Skip to content

Centrifugal Pump Maintenance

20 min read Training Guide

Read a pump curve, keep suction conditions healthy, isolate a pump safely, start and stop it the right way, troubleshoot low flow and noise, and check the clearances that wear inside it.

Table of contents

Centrifugal pumps move water, chemicals, coolant and product in plants, buildings and treatment systems. When one fails, a line stops, a tank overflows or a boiler runs short of water. Pump trouble often starts outside the pump: a starved suction, a pump run far from where it was designed to run, pipe pulling on the casing or a shaft out of line. A good technician learns to read the pump's gauges and its curve before reaching for tools.

What You Will Be Able to Do

  • Name the main parts of a centrifugal pump and what wears.
  • Read a pump curve and tell whether a pump is running near its best efficiency point.
  • Convert gauge pressure to feet of head for a quick field check.
  • Spot cavitation and the suction problems that cause it.
  • Isolate, start, stop and troubleshoot a pump using its maker's procedure.

How a Centrifugal Pump Works

Liquid enters the center of a spinning impeller, at the eye. The vanes fling it outward, and the casing (often a spiral called a volute) turns that speed into pressure at the discharge.

Part Job What wears or fails
Impeller Adds energy to the liquid Erosion, cavitation pitting, clogging
Casing or volute Collects flow, builds pressure Erosion, corrosion
Wear rings or impeller clearance Limit leakage from discharge back to suction Clearance opens, flow drops
Shaft and sleeve Carry the impeller, protect the shaft at the seal Runout, scoring
Packing or mechanical seal Seal where the shaft leaves the casing Leaks, heat
Bearings and frame Hold the shaft in place Heat, noise, oil contamination
Coupling Connects pump to motor Wear from misalignment

A closed impeller has walls on both sides of the vanes and runs inside wear rings. An open impeller has vanes exposed on one side and runs a set gap from the casing or a wear plate. That gap is adjustable on many pumps.

Reading a Pump Curve

The maker's pump curve plots head (how high the pump can lift the liquid, in feet) against flow (gallons per minute). Head falls as flow rises. The curve sheet also shows efficiency, power and the NPSH required at each flow.

The best efficiency point (BEP) is the flow and head where efficiency peaks. Near BEP, the pump runs smoothest, with the least vibration and noise. The Hydraulic Institute calls the band around BEP the preferred operating region. Depending on the pump's design, it can be anywhere from 90 to 110 percent of BEP flow up to 70 to 120 percent.

Where it runs What happens
Near BEP Smooth running, long seal and bearing life
Far left (low flow) Recirculation inside the pump, heat, vibration, shaft deflection
Far right (high flow) Higher NPSH need, cavitation risk, motor overload
No flow at all The liquid heats fast and can flash to vapor

Warning: Never run a pump with its suction valve closed or its piping blocked, and do not keep it running against a closed discharge valve past the moment of start-up. One pump maker's manual (Goulds 3196) warns this can cause rapid heating and vaporization of the liquid, a risk of explosion and serious injury.

Worked Example: Pressure to Head

Gauges read pressure, but curves show head. For a field check, convert with this formula, using the specific gravity (SG), which is the liquid's weight compared with water:

Head in feet = pressure in psi x 2.31 ÷ SG

A water pump (SG 1.0) shows 4 psi at the suction gauge and 62 psi at the discharge gauge, with both gauges at the same height.

  1. Pressure the pump adds: 62 - 4 = 58 psi.
  2. Head: 58 x 2.31 ÷ 1.0 = 134 feet.
  3. On the curve, 134 feet falls at about 410 gpm, and BEP is 450 gpm. The pump is running at about 91 percent of BEP flow, close to its best.

If the same pump moved a brine with an SG of 1.2, the same 58 psi would mean only 58 x 2.31 ÷ 1.2 = 112 feet of head. Always use the SG of the liquid in the pipe. This check ignores the small velocity difference between the flanges, so treat it as a quick test, not a performance test.

Suction Conditions and Cavitation

NPSH (net positive suction head) is how far the liquid at the pump inlet is above the pressure where it would boil. The system provides NPSH available (NPSHA). The pump needs NPSH required, shown on the curve. Curves commonly show NPSH3, which the Hydraulic Institute defines as the NPSH at which head has already dropped 3 percent from cavitation, so the pump is already cavitating there. NPSHA must stay above the curve value with a margin.

Cavitation happens when the pressure at the impeller eye drops low enough that the liquid boils into vapor bubbles. The bubbles collapse as pressure rises again, and each collapse chips the metal.

Signs of cavitation:

  • A sound like gravel or marbles running through the pump.
  • Discharge pressure and flow that bounce or fall.
  • Pitting on the impeller vanes near the eye.

Look first at the suction side: a clogged strainer, a low tank level, hot liquid that is closer to boiling, a partly closed suction valve, or suction pipe that is too small or has too many fittings. Running far right on the curve also raises the NPSH the pump needs. The Goulds 3196 manual says a rise of 5 psi in the pressure drop across a suction strainer means it needs cleaning.

Suction piping rules from the same manual:

  • Never throttle flow on the suction side. Control flow with the discharge valve.
  • Make the suction pipe one or two sizes larger than the pump inlet, never smaller.
  • Use an eccentric reducer at the pump inlet with the flat side on top, so no air pocket forms.
  • Keep the suction line free of high spots where air can collect.

Isolate the Pump Before You Work on It

Lock out the motor under your site's procedure before any repair. A pump also holds energy in its liquid:

  1. Close and lock the suction and discharge valves, and any seal flush, cooling or steam lines.
  2. Drain and vent the casing to a safe place, and confirm zero pressure at a gauge or drain.
  3. Read the safety data sheet for the liquid and wear the PPE it calls for. Let a hot pump cool.
  4. Watch for a leaking check valve. Backflow from a running pump nearby can pressurize the casing or spin the shaft backward.

Starting and Stopping

Follow the maker's start-up procedure. The Goulds 3196 manual's version:

  1. Check rotation before the pump is coupled. With power locked out, remove the coupling spacer. Then unlock, jog the motor, confirm it turns the way the arrow on the pump shows, and lock out again. Reverse rotation can make metal parts rub and break containment.
  2. Prime the pump. Fill the casing and suction line with liquid and open the vents until liquid, not air, comes out. Unless it is a self-priming design, a centrifugal pump cannot pump air.
  3. Open the suction valve fully, and turn on any seal flush, cooling or recirculation lines.
  4. Check the seal is ready. A cartridge seal's setting clips must come off before start-up, and new packing must be allowed to leak.
  5. Close or crack the discharge valve, as system conditions call for, and start the motor. Then open the discharge valve slowly to the flow you need.
  6. Check right away that discharge pressure comes up. If it does not, stop, prime again and restart.
  7. Watch amps, noise, vibration and bearing temperature for the first minutes.

To shut down, the same manual says to close the discharge valve slowly, then stop and lock out the driver.

Rounds: What to Check on a Running Pump

Check Normal A change means
Suction and discharge pressure Steady, near the last reading Falling suction: strainer or tank level. Falling discharge: wear, air, speed
Motor amps Near the last reading, under the nameplate High: heavier liquid, high flow, rubbing. Low: low flow, air
Noise Steady hum Gravel sound: cavitation. Knock or rumble: bearings or recirculation
Bearing temperature Steady Rising: lubrication, alignment or bearing wear
Seal or packing Seal dry, packing dripping steadily Seal dripping or packing smoking
Oil level and color At the mark, clear Milky oil means water is getting in

Grease or oil the bearings on the maker's schedule with the lubricant it names. Too much grease heats a bearing, just as too little wears it.

Troubleshooting

These causes come from the Goulds 3196 troubleshooting table.

Symptom Likely causes
No liquid delivered Not primed, suction or impeller clogged, wrong rotation, suction lift too high
Low flow or head Air leak at a gasket or seal, impeller partly clogged or worn, clearance too large, suction valve not fully open
Starts, then stops pumping Lost prime, air or vapor pockets in the suction, air leak
Bearings run hot Misalignment, wrong or low lubricant, poor cooling
Noisy or vibrating Misalignment, clogged impeller, bent shaft, loose foundation, worn bearings, unsupported piping, cavitation
Motor draws too much power Pumping too much flow at low head, liquid heavier than expected, packing too tight, parts rubbing

Clearances, Wear, and Pipe Strain

When a pump loses flow slowly over months, internal clearance is often the reason. Liquid slips from the discharge side back to the suction through the opened gap.

  • Open impellers are reset to the maker's clearance with a dial indicator or feeler gauges. The Goulds 3196 table sets the cold clearance on its smallest frame at 0.005 inch for liquids up to 200°F, with larger values on bigger frames and for hotter liquids, so the impeller does not touch the casing as parts expand. Always use the table for your pump and temperature.
  • Wear rings on closed impellers are replaced when clearance reaches the maker's limit. A common shop rule is to replace them when the clearance has doubled, but some makers set the limit lower, so use the manual.
  • Shaft and sleeve. The Goulds 3196 manual says a sleeve runout over 0.002 inch total indicator reading (TIR) means something is wrong to find before reassembly. Replace a grooved or pitted sleeve.
  • Impeller. Look for cavitation pitting near the eye, erosion at the vane tips and corrosion. Pitting at the eye sends you back to the suction side.

Pipe strain, piping pulling or pushing on the pump flanges, bends the casing and wears seals and bearings. Support the piping so the flanges line up on their own, never pull them together with the bolts, and check for strain with indicators on the coupling as part of alignment. Shaft alignment and bearing replacement follow their own procedures. Recheck alignment after any work that moves the pump, motor or piping.

Common Mistakes

  • Throttling the suction valve. It starves the pump and causes cavitation.
  • Running it dry or deadheaded. Seconds of dry running can wreck a mechanical seal, and a closed discharge can flash the liquid to vapor.
  • Skipping the rotation check. Running backward can damage the pump on its first start.
  • Replacing the seal without asking why it failed. Misalignment, pipe strain and cavitation kill the next one too.
  • Using water's SG for every liquid. Head and power figures come out wrong.

Check Your Understanding

1. A pump that used to give 55 psi at the discharge now gives 48 psi at the same valve setting. Suction pressure and amps are about the same. What do you suspect?

Internal wear. An open impeller clearance or worn wear rings let liquid slip back to the suction. Check the clearance against the maker's table at the next shutdown.

2. An operator says a pump sounds like it is full of gravel since the tank level dropped. What is happening, and what do you check?

Cavitation from low NPSH available. Check the tank level, the suction strainer and that the suction valve is fully open. Do not close the suction valve to quiet it.

3. A motor was rewired during a repair. What do you do before you couple it to the pump?

Lock out, remove the coupling spacer, then unlock, jog the motor and confirm rotation matches the arrow. Lock out again before you install the spacer.

Key Takeaways

  • Pump trouble often starts outside the pump: suction conditions, operating point, pipe strain and alignment.
  • Run a pump near its best efficiency point. Never run it dry, and never for long against a closed valve.
  • Head in feet = psi x 2.31 ÷ SG. Use the real SG of the liquid.
  • Cavitation sounds like gravel and pits the impeller eye. Fix the suction side, and never throttle the suction valve.
  • Check rotation uncoupled, prime before start, and use the maker's clearance tables for wear parts.