Every load of laundry sends lint out through the dryer's exhaust vent, and some of it sticks inside. As lint builds up, air slows, the dryer runs hotter and longer, and the lint itself becomes fuel. In a U.S. Fire Administration study of residential dryer fires, using 2008 to 2010 data, failure to clean was the leading factor, at 34 percent. Cleaning a vent is simple work with the right tools, and it is also a chance to catch vent problems that no amount of cleaning will fix.

What You Will Be Able to Do

  • Recognize the signs that a vent is restricted
  • Check a vent against the code rules for material, joints, length and termination
  • Work out a vent's equivalent length, including its elbows
  • Clean a vent from the dryer to the outside hood with a rotary brush
  • Test airflow and record what you found

Signs a Vent Needs Cleaning

  • Clothes take more than one cycle to dry.
  • The dryer's top or the laundry room gets unusually hot.
  • The outside hood's flap barely opens, or does not move, while the dryer runs.
  • Lint collects around the outside hood, or behind the dryer.
  • A burning smell during drying.
  • A blown thermal fuse in the dryer.

What the Code Expects

Houses, duplexes and townhouses fall under Section M1502 of the International Residential Code, as adopted by the state or city, and the rules below come from it. Apartment buildings usually fall under the International Mechanical Code, which has similar rules for household dryers, and commercial laundries follow that code and the equipment maker. Your adopted edition and local amendments win, and so do the dryer maker's installation instructions. Where the maker sets a shorter length or a stricter rule, follow the maker.

Item The rule
Where it ends Outdoors. Never into an attic, crawl space, chimney, or another duct
Outside hood A backdraft damper that closes when the dryer stops, and no screen
Distance from openings At least 3 feet from doors, windows and other openings, unless the maker says otherwise
Duct material Rigid metal with a smooth inside, at least 0.0157 inch thick (No. 28 gauge), 4 inches in diameter
Joints The inside end of each piece points in the direction of airflow. Joints sealed and fastened, with no screws sticking more than 1/8 inch into the duct
Transition duct The flexible piece behind the dryer: one listed length (UL 2158A), no longer than 8 feet, never hidden inside a wall, floor or ceiling
Length By the dryer maker's instructions, or a 35-foot default, reduced for each elbow
Booster fan Allowed only if listed for dryer exhaust and installed per its instructions
Runs over 35 feet A permanent label within 6 feet of the duct connection giving the equivalent length

White vinyl hose and thin foil accordion hose are not allowed as the transition duct unless they carry the UL 2158A listing. Plastic vent hose melts and traps lint in its ridges.

Work Out the Equivalent Length

Every elbow slows the air as much as a length of straight duct. Under the code's default method, the duct, not counting the transition duct, can be up to 35 feet. Take 5 feet off for each 90-degree elbow and 2 1/2 feet for each 45-degree elbow, using the standard 4-inch radius mitered elbows in the code's table. Long-radius elbows count for less.

Worked example. A vent runs 20 feet of straight duct with three 90-degree elbows and one 45-degree elbow.

  • Straight duct: 20 feet
  • Three 90-degree elbows: 3 x 5 = 15 feet
  • One 45-degree elbow: 2.5 feet
  • Equivalent length: 20 + 15 + 2.5 = 37.5 feet

That is over the 35-foot default. Check the dryer maker's table, which may allow more or less. If it does not allow 37.5 feet, the fix is a shorter route, fewer or long-radius elbows, or a listed booster fan. Cleaning will not solve a vent that is too long, so report it.

Tools and Gear

  • A rotary vent brush kit with flexible rods that screw together, driven by a drill
  • A shop vacuum, ideally with a fine filter
  • A screwdriver or nut driver, and foil tape listed for duct sealing
  • A flashlight or inspection camera
  • Gloves, eye protection, and a dust mask or respirator, since lint and dust come out in clouds
  • Drop cloths for the floor
  • A ladder, with fall protection for any roof termination

Cleaning the Vent

  1. Turn the dryer off and unplug it. A gas dryer can be moved on its connector only by someone qualified or allowed by their employer to move a gas appliance. Pull it out slowly and do not strain the connector. If it is a steam dryer, mind its water line too.
  2. Disconnect the transition duct from the dryer and the wall. Inspect it. Replace it if it is crushed, torn, plastic, or not listed.
  3. Vacuum the dryer's outlet and the lint screen slot. Lint packs into the duct below the lint screen.
  4. Open the outside hood. Remove its cover or hold the flap open. Pull out nests and packed lint with a gloved hand. Check that the flap moves freely and that no screen or cage covers it.
  5. Brush the duct. Attach the brush to the first rod and the drill. Feed it into the duct while it spins, adding rods as you go. Run it back and forth in short sections, and ease it through elbows. Do not force it.
  6. Keep the drill turning clockwise. Running it in reverse can unscrew the rods and leave a brush stuck inside the duct.
  7. Catch the lint. Have a helper hold the vacuum at the far end, or vacuum the pile that comes out. Work from both ends on a long run.
  8. Inspect the run where you can reach it. Look for joints that have pulled apart, crushed sections, and screws through the duct catching lint.
  9. Reseal and refasten any loose joints with listed foil tape and a fastener that does not reach into the airflow. Do not use ordinary cloth duct tape.
  10. Reconnect the transition duct in the shortest, straightest path you can, without crushing it when the dryer goes back. Leave room behind the dryer.

Warning: A rooftop termination puts you at the roof edge. Use the fall protection your employer requires, and do not work a roof in wet or icy weather. Roof hoods clog faster because lint falls back down into them.

Test and Record

Run the dryer on high heat, empty, for a few minutes. Go to the outside hood. The flap should open fully and you should feel strong, warm airflow. Compare it with what you felt before cleaning. Check the joints you can see indoors for lint or air leaking out.

Record the date, the vent's route and equivalent length, its condition, what you replaced, and any problems you could not fix. A vent that was badly clogged after a short time often has a problem, such as a crushed section, an elbow too many, or a screened hood.

Problems Cleaning Will Not Fix

Finding Why it matters What to do
Vent ends in an attic, crawl space or garage ceiling Hot, damp, lint-laden air inside the building Report it for rerouting to the outdoors
Equivalent length over the limit Slow drying and fast lint buildup Report it for a shorter route or a listed booster fan
Screen on the hood Traps lint at the outlet Replace the hood with a damper-type hood
Plastic or unlisted foil duct hidden in a wall Melts, sags and traps lint Report it. Replacing hidden duct is construction work
Two dryers tied into one duct A dryer's exhaust must be independent unless the system was engineered for more Report it
Duct crushed inside a finished wall Cannot be cleaned open Report it for repair

Changes to the vent's route, new holes through walls or roofs, and booster fan wiring may need a permit and the right trade. Your job is to find these problems and report them clearly.

Common Mistakes

Mistake What it costs
Cleaning the duct but not the hood The blockage stays at the outlet
Running the brush drill in reverse Rods unscrew and a brush stays in the duct
Pushing the dryer back onto the transition duct A crushed duct and a slow dryer
Fastening joints with long screws Lint catches on the screw tips and builds a plug
Leaving a screen on the hood A blocked vent within weeks
Not recording an over-length run The same clog, and the same risk, next time

Check Your Understanding

1. A vent has 12 feet of straight duct, two 90-degree elbows and two 45-degree elbows. What is its equivalent length under the code's default table?

12 + (2 x 5) + (2 x 2.5) = 27 feet. That is within the 35-foot default, but check the dryer maker's limit, which wins.

2. Behind a dryer you find a white vinyl hose running into the wall. What do you do?

Replace the exposed part with a listed transition duct, and report that unlisted plastic duct may run inside the wall, where transition duct is not allowed at all.

3. The outside hood has a wire screen over it "to keep birds out." Is that allowed?

No. The code does not allow a screen at the termination, because it traps lint. Replace it with a hood that has a backdraft damper.

4. You finish cleaning, and the hood flap still barely opens with the dryer running on high heat. What next?

Look for a crushed transition duct behind the dryer, a disconnected or crushed section, or a run that is too long. Inspect the run with a camera if you have one, and report what you find.

Key Takeaways

  • Lint buildup is a leading factor in dryer fires, so vents need regular cleaning.
  • The vent ends outdoors, with a damper and no screen.
  • Rigid smooth metal duct, joints pointing with the airflow, and no screws into the airstream.
  • Count elbows: 5 feet for each 90 and 2 1/2 feet for each 45 under the default table. The dryer maker's limit wins.
  • Keep the brush drill turning clockwise, clean the hood as well as the duct, and test the airflow when you finish.
  • Report problems cleaning cannot fix, and record what you found.