Flattening a Subfloor for Finish Flooring

15 min read Training Guide

Measure a subfloor for flatness, grind highs and patch lows, pour self-leveling underlayment, and test concrete and wood for moisture before any flooring goes down.

Table of contents

Every finish floor shows what is under it. A dip under a plank floor lets the joints flex and break. A hump under tile cracks it. Wet concrete lifts vinyl, softens glue and grows mold. Fixing any of these after the floor is down means tearing it out.

What You Will Be Able to Do

  • Tell the difference between flat and level, and why flooring cares about flat.
  • Measure a floor against the tolerance the flooring calls for.
  • Choose between grinding, patching and self-leveling underlayment.
  • Mix and pour self-leveling underlayment without the common failures.
  • Run or read a moisture test on concrete and wood.

Flat Is Not Level

Flat means the surface has no humps or dips over a short distance. Level means it does not slope. A floor can slope 1/2 inch across a room and still be flat enough for any flooring, so flatness is what you measure. Level matters for things like cabinets and appliances.

How Flat Is Flat Enough

The flooring maker's instructions set the tolerance and control the warranty. These are common published values.

Flooring Typical flatness Source
Tile, all edges under 15 inches 1/4 inch in 10 feet, 1/16 inch in 12 inches ANSI A108.02
Tile with any edge 15 inches or longer 1/8 inch in 10 feet, 1/16 inch in 24 inches ANSI A108.02
Floating LVP and laminate Often 3/16 inch in 10 feet, some 1/8 inch in 6 feet Product instructions
Nail-down hardwood 1/4 inch in 10 feet or 3/16 inch in 6 feet NWFA
Glue-down hardwood 3/16 inch in 10 feet or 1/8 inch in 6 feet NWFA

Glue-down resilient flooring and sheet goods also need a smooth surface, because ridges, trowel marks and nail heads show through thin material. Carpet hides small dips but still needs a sound, smooth base.

Measuring the Floor

  1. Clear and vacuum the room, since debris gives false readings.
  2. Lay a straight 10-foot straightedge on the floor. Slide it across the room in rows, then crosswise and diagonally. Use a 6-foot straightedge where the spec uses 6 feet.
  3. Where light shows under it, measure the gap with a tapered gauge, feeler gauge or stacked shims.
  4. If the straightedge rocks, it is sitting on a hump. Find the high point.
  5. Mark lows in one color, with the depth written in the middle, and highs in another color.
  6. On big floors, map the highs and lows on a grid with a laser and receiver.

Worked example. A floating vinyl plank floor calls for 3/16 inch in 10 feet. The gap under the 10-foot straightedge at a dip is 3/8 inch, which is 3/16 inch over the limit. Fill the dip with patch, feathered out over several feet, and aim close to zero, since your reading has some error.

If instead the straightedge rocks on a panel seam with 1/4-inch gaps at each end, that is a hump. Sand the seam down rather than filling the whole floor up to it.

Choosing the Fix

Problem Usual fix
A few small dips Trowel-applied patch, feathered at the edges
Many dips or a broad low area Self-leveling underlayment
High spots in concrete Grind them down
High panel edges or seams on wood Sand or plane, then refasten
Humps over crowned joists Plane the joists before sheathing, or sand and feather on an existing floor
Loose, squeaky or soft areas Screw down or replace the panels first
Cracks in concrete Hairline cracks: patch or membrane. Wide, moving or offset cracks: stop and ask an engineer

Patching makes a floor flat. It does not make it stiff. A wood floor that bounces needs framing work before any finish flooring.

Patch Products

Use a floor patch the flooring maker accepts. Cement-based patches are the most common, and many feather to nothing. Gypsum-based products are interior only, and some flooring makers limit them. Drywall joint compound is not a floor patch. It is soft, moisture breaks it down, and adhesives do not hold to it.

Preparing Wood Subfloors

  1. Screw loose panels to the joists at the spacing the panel or flooring maker calls for, and set every fastener head flush or just below.
  2. Sand high seams and edges flat.
  3. Replace water-damaged, swollen, delaminated or soft panels.
  4. Fill seams, holes and dips with a patch the maker rates for wood subfloors, using its primer if required.
  5. Vacuum before the next step.

Self-leveling underlayment over wood usually needs a primer, a minimum thickness, and often metal lath or mesh fastened down. Follow the product's wood-subfloor instructions.

Preparing Concrete

  1. Remove paint, sealers, curing compounds, old adhesive and dirt. Bonded products cannot stick to a sealed or dirty slab.
  2. Grind high spots and open up a slick surface. Use a grinder with water or dust collection, as OSHA's silica rule requires for walk-behind and handheld floor grinders, and follow your site's silica plan.
  3. Vacuum with a HEPA vacuum. Do not dry sweep.

Warning: Old black adhesive and old vinyl flooring residue may contain asbestos. Do not grind, sand or scrape it dry until it has been tested.

Pouring Self-Leveling Underlayment

Self-leveling underlayment (SLU) is a cement-based powder you mix with water and pour. It flows into low areas and cures to a flat, hard surface. It moves fast, and mistakes cure in place, so plan before you open a bag.

  1. Read the data sheet. Note the minimum and maximum pour depth, the primer, the exact water per bag, the flow time, the walk-on time, and the wait before flooring.
  2. Prime the surface with the maker's primer. Primer helps the bond and seals porous concrete so air does not bubble up and leave pinholes.
  3. Dam everything. SLU flows like water. Seal cracks, holes, floor drains, pipe penetrations and gaps at walls with foam, tape or sealant. Build a dam at doorways and open edges, or it will run into ducts and the room next door.
  4. Set depth marks. Use gauge pins or laser marks so you know how deep to pour in each area.
  5. Mix full bags with measured water. Use a marked bucket, a mixing paddle and the mix time on the bag. Extra water makes SLU weak, dusty and prone to cracking. Do not guess.
  6. Pour in ribbons and keep a wet edge. Pour each batch against the last one before it loses flow. Work away from the exit so you do not trap yourself.
  7. Spread with a gauge rake or smoother, and roll with a spiked roller to release air. Wear spiked shoes to walk in it.
  8. Protect the cure. Keep drafts, direct sun and heaters off the pour. Fast drying cracks it.
  9. Check it again with the straightedge once it is hard enough to walk on.

A large pour needs enough people, or a pump, to keep the edge wet. A batch poured against a hardened edge leaves a ridge.

Testing for Moisture

Moisture from below breaks down adhesives, swells flooring and grows mold. Test with the method the flooring maker names, and compare the result with that maker's limit.

Concrete

Test How it works Notes
ASTM F2170 (in-slab relative humidity) Probes sit in holes drilled into the slab The method most makers name
ASTM F1869 (calcium chloride) A dish of calcium chloride under a sealed dome absorbs moisture for 60 to 72 hours Reports pounds per 1,000 square feet per 24 hours, and reflects mainly the top of the slab
Taped plastic sheet Look for darkening or condensation Shows moisture is present. Does not prove the slab is dry enough
Handheld concrete meter Quick surface reading Screening only

For an F2170 test:

  1. Bring the slab and the air above it to normal service temperature and humidity for at least 48 hours first.
  2. Drill holes to 40 percent of the slab thickness for a slab that dries only from the top, or 20 percent for a slab that dries from top and bottom.
  3. Clean and line each hole, seal the sensor in, and wait at least 24 hours before the reading counts.
  4. Test three spots for the first 1,000 square feet and at least one more for each additional 1,000 square feet, including spots within 3 feet of each exterior wall.

Worked example. A 3,000-square-foot slab is 4 inches thick on a vapor retarder, so it dries only from the top. Drill to 40 percent of 4 inches, which is 1.6 inches. You need 3 tests for the first 1,000 square feet and 2 more for the next 2,000, so 5 tests. If the flooring's limit is 85 percent RH and one reading is 91 percent, the slab is not ready there.

Wood

Use a pin-type moisture meter on the subfloor in many spots, and read the flooring too when it is wood. NWFA guidance keeps a wood subfloor within 4 percentage points of solid strip flooring under 3 inches wide, and within 2 points for wider planks. Wet subfloors often point to a crawlspace problem, such as missing ground cover or poor drainage.

When Readings Are Too High

Give the slab more time with the heating and cooling running, use a moisture mitigation system the flooring maker approves, choose a floor and adhesive rated for the level, or fix the source. Installing over a failed test can void the warranty and leave the installer paying for the failure.

Common Mistakes

Mistake What it costs
Checking with a 4-foot level only Missed dips that show under the new floor
Skipping the primer under SLU Pinholes, bubbles and a weak bond
Adding extra water to SLU Weak, cracking surface
Installing without a moisture test Cupped wood, lifted vinyl, mold

Working Safely

  • Cement-based patch and SLU are alkaline and can burn skin and eyes. Wear gloves and eye protection.
  • Mixing powder raises dust. Mix where it is ventilated, and wear the respirator your employer's plan calls for.
  • Use a cart for heavy bags, and wear knee pads.

Check Your Understanding

1. A floor slopes 1/2 inch from one wall to the other but has no dips. Is it ready for floating vinyl?

Most likely yes, if it meets the flatness spec. Vinyl needs flat, not level.

2. You plan to install 24-inch tile. A 10-foot straightedge shows a 3/16-inch dip. Is that acceptable?

No. Tile with an edge 15 inches or longer needs 1/8 inch in 10 feet. Patch the dip.

3. A helper wants to add an extra quart of water to make the SLU easier to spread. What do you say?

No. Use the water the bag calls for. Extra water weakens it and causes cracking and dusting.

4. A slab is 5 inches thick and dries only from the top. How deep do you drill for an F2170 test?

40 percent of 5 inches, which is 2 inches.

Key Takeaways

  • Flooring needs flat, and the flooring maker sets the tolerance.
  • Measure in many directions with a long straightedge, and mark highs and lows.
  • Grind highs, patch small lows, and pour SLU for broad lows.
  • Prime, dam, measure water, and keep a wet edge when pouring SLU.
  • Test moisture with the method the flooring maker names, and do not install over a failed test.