Flooring Transitions and Thresholds
Choose the right molding where two floors meet, measure the height difference, keep level changes within accessibility limits, and fasten transitions without pinning a floating floor.
Table of contents
Wherever one floor ends, a transition covers the edge. It protects the cut edge from traffic, hides the expansion gap of a floating floor, and turns a height difference into something people can walk over without tripping. A transition chosen by color alone often fails. It ends up too low, too high, screwed through a floor that needed to move, or sitting where the door cannot close over it.
The flooring maker's instructions say which moldings fit its product and how they fasten. Accessibility rules and the building code set limits on height changes. Where those disagree with a habit you have picked up, they win.
What You Will Be Able to Do
- Name the common transitions and where each one goes.
- Measure the finished height of each floor and the difference between them.
- Keep changes in level within the limits that apply to accessible routes.
- Fasten a transition so a floating floor can still move.
- Place a doorway transition where it looks right and the door still works.
Common Transitions
| Molding | Where it goes |
|---|---|
| T-molding | Between two floors at about the same height, or across a break in a floating floor |
| Reducer | From a higher floor down to a lower one |
| End cap or threshold | Where a floor stops at a vertical surface, such as a sliding door track or a hearth |
| Stair nose | At the edge of a step or landing |
| Quarter round or base shoe | Along walls, covering the expansion gap |
| Carpet edge strip | Where carpet ends against a hard floor |
| Overlap reducer | From a floating floor down to a lower floor, resting on the floating floor |
Many makers sell matching moldings, and some sell a single profile that converts to several of these. Moldings made for a floating floor have a gap underneath and fasten to a track or to the subfloor, never to the floating planks.
Measure Before You Choose
Every floor has a build-up, the total height from the subfloor to the top of the finish. Add up its layers.
| Floor | Typical layers to add |
|---|---|
| Click vinyl plank | Plank, plus any attached or added pad |
| Laminate | Plank, plus underlayment |
| Tile | Backer board or membrane, mortar bed, tile |
| Sheet vinyl or glue-down vinyl | Underlayment panel if any, plus the vinyl |
| Carpet | Tack strip area: cushion plus carpet |
| Hardwood | Underlayment paper, plus the board |
Measure actual materials with a tape or calipers. Product thicknesses are often listed in millimeters. Divide millimeters by 25.4 to get inches.
Worked Examples
Plank to tile. A vinyl plank is 6.5 mm with its pad, which is 6.5 / 25.4 = about 1/4 inch. The tile next to it builds up to 3/4 inch with backer and mortar. The difference is 1/2 inch, so you need a reducer that drops 1/2 inch.
Plank to plank. Laminate at 12 mm plus a 2 mm pad is 14 mm, about 9/16 inch. Click vinyl in the next room is about 1/4 inch. The difference is about 5/16 inch, too much for a T-molding. Use a reducer, or raise the lower floor with an underlayment the maker allows.
Sheet vinyl to carpet. Sheet vinyl over a 1/4-inch underlayment panel is about 3/8 inch. Carpet on a 7/16-inch cushion stands much higher, but it compresses. A carpet edge strip or carpet-to-hard-surface reducer handles this.
Tile to an old vinyl hall. Tile at 3/4 inch meets old sheet vinyl at 1/8 inch, a 5/8-inch drop. That is more than a reducer should cover on an accessible route, as the next section explains. Raise the lower floor, recess the tile, or talk to your supervisor before installing anything.
Keeping Height Changes Safe
People trip on edges, and wheels catch on them. The 2010 ADA Standards for Accessible Design set these limits for changes in level on accessible routes:
| Height change | What is allowed |
|---|---|
| Up to 1/4 inch | May be vertical |
| Over 1/4 up to 1/2 inch | Must be beveled no steeper than 1:2 |
| Over 1/2 inch | Must be treated as a ramp |
A 1:2 slope rises 1 unit for every 2 units across. A 1/2-inch rise needs at least 1 inch of bevel.
The same standards limit thresholds at doorways to 1/2 inch high, with a narrow exception for some existing thresholds. Carpet on an accessible route must have its exposed edges trimmed along their whole length and fastened down, and that trim must meet the same level-change limits.
These rules apply to public places such as stores, offices and the common areas of many buildings. Private homes are usually outside them, but the trip hazard is the same. A 1/2-inch lip in a home hallway still catches toes. Local codes and building owners may set stricter rules.
For carpet with no transition molding, CRI 104 and 105 say the hard floor's edge should be no more than 1/16 inch higher than the total carpet thickness, and the carpet edge needs a bead of seam sealer at least 1/8 inch wide along the full length.
Where the Transition Goes
- Doorways. Center the molding under the door, so it sits under the slab when the door is closed. Then neither room sees it from the other.
- Open floor plans. Line the break up with a wall corner, a column or a change in use, where it looks planned.
- Floating floor breaks. Put them where the maker requires them, such as at narrow doorways or past a maximum run length.
- Exterior doors. The floor stops at the threshold with an end cap or reducer. Leave the gap the floor needs and seal it with a flexible sealant, not grout or rigid filler.
Fastening
The rule is simple: a transition holds down the floor next to it, but it must not hold down a floating floor.
- Track systems. Many floating-floor moldings snap into a metal or plastic track. Fasten the track to the subfloor in the gap between the two floors, with screws into wood or with adhesive on concrete.
- Glue-down moldings. Some moldings glue to the subfloor or to a glue-down floor. Use the adhesive the maker names.
- Nails and screws. Fasten only into the subfloor or into a fixed floor, never through floating planks.
- Concrete. Masonry screws or anchors hold a track. Check for radiant heat tubing or wires in the slab first. Where you are not certain of their depth and location, use adhesive instead.
Leave the expansion gap on the floating side. A T-molding covering a floating floor should overlap the planks without pressing on them.
Installing a T-Molding over a Track
- Install both floors, leaving a gap between them as wide as the molding's stem plus each floor's expansion gap.
- Cut the track to the doorway width and fasten it to the subfloor, centered in the gap.
- Cut the molding to length with a miter saw, using a fine-tooth blade.
- Line up the molding's stem with the track and tap it down with a rubber mallet and a scrap block.
- Check that the planks on both sides can still move under the molding.
Doors and Clearance
A new floor raises the floor height, and the transition may raise it a little more.
- Check the swing. Open and close the door over the new floor and molding before you finish. A door that drags will tear up a transition.
- Trim the door if needed. Take the door off its hinges and cut the bottom with a guided saw, leaving clearance over the highest point it swings across.
- Fire-rated doors. These are labeled on the edge. Fire code limits the gap under them. Do not trim one without your supervisor's approval.
- Door stops and jambs. Undercut casings and door stops so the floor slides under them, instead of butting into them with a caulked gap.
Fixing Problems
| Symptom | Likely cause | Fix |
|---|---|---|
| Floating floor peaks at a doorway | Molding screwed through the planks | Fasten to a track or subfloor only |
| Molding rocks or clicks | Track loose, or floors at different heights | Refasten the track, choose the right profile |
| People trip at the edge | Height change too large or not beveled | Use a reducer within the limits, or raise the low floor |
| Carpet edge frays at the strip | No edge trim, or edge not sealed | Install the right strip and seal the edge |
| Door scrapes the molding | Floor raised the height | Trim the door, or choose a lower molding |
Common Mistakes
| Mistake | What it costs |
|---|---|
| Choosing a molding by color only | Lips and gaps that trip people |
| Screwing a T-molding through a floating floor | Peaking and a voided warranty |
| Skipping the height measurement | A reducer that sits too high or too low |
| Placing the break in the middle of a doorway | A strip that shows from both rooms |
| Drilling into a slab with radiant heat | A damaged heating system and a costly repair |
Check Your Understanding
1. A store's new vinyl floor meets an existing tile floor 3/8 inch higher. What do you need?
A reducer beveled no steeper than 1:2, since the change is over 1/4 inch but not over 1/2 inch. The bevel must be at least 3/4 inch wide.
2. A T-molding between two floating floors is screwed through both floors into the subfloor. What will happen?
The floors cannot move under it, and they can peak or gap. The molding should fasten to a track or to the subfloor in the gap.
3. Laminate is 9/16 inch high and the next room's vinyl plank is 1/4 inch. Will a T-molding work?
No. The difference is about 5/16 inch. Use a reducer, or bring the lower floor up with an allowed underlayment.
4. You are about to screw a track into a slab and are not sure whether it has radiant heat. What do you do?
Find out first. Where you cannot confirm the location and depth of the heating, glue the track instead of drilling.
Key Takeaways
- Measure each floor's full build-up before choosing a molding.
- On accessible routes, keep changes in level to 1/4 inch vertical or 1/2 inch beveled at 1:2. More than that is a ramp.
- Fasten transitions to a track, the subfloor or a fixed floor, never through a floating floor.
- Center doorway transitions under the closed door, and check the door swing.
- The flooring maker and the local code have the final word.