Fluid Power Safety
Respond to an injection injury, check for leaks without touching them, control hose whip, and treat accumulators, raised loads and compressed air as live energy.
Table of contents
Hydraulic and pneumatic systems store energy you cannot see. A line can hold thousands of psi with the pump off. A pinhole leak can push oil through your skin without much pain. A hose that lets go can whip hard enough to break bones, and a ram held up by oil can drift down onto your arm. None of this needs a running machine. These hazards sit on top of the lockout rules, so they are the things to watch for after the locks are on and before you reach in.
What You Will Be Able to Do
- Recognize an injection injury and get the right care fast.
- Look for leaks without putting any part of your body in the stream.
- Prevent and contain hose whip on air and hydraulic hoses.
- Treat accumulators and raised loads as live until you prove otherwise.
- Use compressed air without hurting yourself or anyone nearby.
Before You Touch a Fitting
Lock out the machine, then relieve, block and verify every stored energy source the written procedure lists. Remember these limits while you do it:
- A stopped pump is not zero pressure. Check valves, counterbalance valves and closed valve centers trap oil and air in parts of the circuit.
- A gauge only reads its own branch. Know which part of the schematic each gauge can see.
- Pressure can take time to fall. Parker Hannifin, a hose maker, notes in its hose safety rules that it can take several minutes or even hours for pressure to bleed out of a failed hose.
- Never crack a fitting to see if a line is empty. Use the bleed point the procedure names.
Injection Injuries
How They Happen
A stream of fluid under pressure can break the skin and spread into the tissue underneath. The UK Health and Safety Executive reports that serious cases have happened above 100 bar (1,450 psi), and that anecdotal reports put the threshold as low as 7 bar, about 100 psi. Hydraulic hoses, grease guns and airless paint sprayers can all do it.
The danger is how small it looks at first. The wound can be a tiny puncture that barely bleeds and hardly hurts. Over the next hours, the fluid spreads and the tissue swells and dies. HSE notes that within 4 to 6 hours without treatment, the pain can become an intense throbbing that pain medicine does not touch.
Why Minutes Matter
Hand surgeons treat these injuries as an emergency. A 2006 review in the Journal of Orthopaedic Trauma looked at 435 published cases of injection injuries to the arm and hand. Thirty percent ended in amputation. For oil, paint, paint thinner, fuel and similar fluids, the risk of amputation was lower when surgeons cleaned out the wound within 6 hours.
What to Do
- Get clear of the stream and shut the machine down if you can do it without reaching back into the spray.
- Treat it as an emergency, even if it looks like a pinprick. Go to an emergency room now, and have someone else drive you or call 911. Do not wait to see if it gets worse.
- Tell the medical staff it is a high-pressure injection injury. Give them the fluid's name, the system pressure if you know it, and the safety data sheet. Parker's safety rules say even seemingly minor injuries must be treated immediately by a physician who knows how hydraulic fluid damages tissue.
- Do not squeeze the wound or try to push the fluid out.
- Report it to your supervisor, so the leak is fixed and the event is recorded.
Ask your employer, before you need it, which hospital the site uses for injuries like this. Not every emergency room sees them often.
Warning: An injection injury can look harmless for the first hour. If fluid under pressure hit your skin and you see any break, get emergency care right away.
Finding Leaks Without Touching Them
Never feel for a leak with your hand, a finger or any other part of your body. Parker is blunt about it: a pinhole can throw a stream that is hard to see and powerful enough to pass through skin. Ordinary work gloves do not stop it.
Do it this way instead:
- Look for wet spots, drips and oil collecting on the floor or on parts below the leak.
- If you must find a leak while the system is under pressure, pass a piece of cardboard or wood slowly along the hose or fitting and watch for a wet line on it. Keep your hands back and wear a face shield and safety glasses.
- Better still, shut down and relieve pressure, wipe the area clean, then bring the system up while you watch from a safe spot.
- Once you find it, shut down and relieve pressure before you tighten or replace anything. Never tighten a fitting that is under pressure.
Oil spray brings two more hazards. A fine mist reaching a hot surface, such as a furnace, an exhaust manifold or a heater, can catch fire, which is why some systems use fire-resistant fluid. Oil on the floor causes falls. Clean it up and set out absorbent before you move on.
Hose Whip and Flying Fittings
When a hose or fitting lets go under pressure, the free end can whip around with enough force to break bones or knock someone down. A coupling can fly off and hit like a thrown hammer. Air hoses are the usual offenders, because air keeps expanding out of the line as it escapes. A large hydraulic hose can do it too.
Air hoses.
- On construction sites, OSHA 1926.302(b)(7) requires a safety device at the supply or branch line on any air hose over 1/2-inch inside diameter, to reduce pressure if the hose fails. An excess flow valve, which shuts when flow jumps, is one common type.
- Fit a whip check, a short cable restraint, across each hose-to-hose and hose-to-tool joint where a failure could whip.
- Pin or clip twist-lock couplings so they cannot spin apart.
- Never use an air hose to raise or lower a tool. OSHA bans that on construction sites in 1926.302(b)(6).
Hydraulic hoses.
- Never exceed the maker's rated working pressure. Parker notes that an assembly's rating is the lower of the hose's and the fittings' ratings, and that the published burst pressure is for factory testing only.
- Pressure spikes are higher than most gauges show. Parker points out that a gauge reads average pressure and cannot catch a short spike.
- Keep the shields, guards and restraints that came on the machine, especially on hoses near the operator's position.
- When a system comes back up after a repair, stay out of the line of fire of the new hose and fittings.
A failed hose is never patched. It is replaced with an assembly that matches the original.
Warning: If a hose bursts, shut the machine down and leave the area until the pressure has bled off. Do not grab the hose to stop it.
Accumulators
An accumulator is a pressure vessel that stores oil against a charge of gas, usually behind a bladder, piston or diaphragm. It holds two kinds of energy at once: the oil, and the gas behind it.
- Treat every accumulator as charged until proven otherwise. Tobul, an accumulator maker, puts that first in its instructions.
- Draining the oil does not remove the gas. The precharge stays in the shell after the oil gauge reads zero. Opening the gas side or removing the accumulator is a separate job that follows the maker's method.
- Use only dry nitrogen for the precharge. Never use shop air or oxygen. Tobul warns that air or oxygen in contact with oil risks combustion or explosion.
- Leave precharge checks to trained people with the maker's charging kit. The oil side has to be at zero pressure before the gas side can be checked.
- Never weld on an accumulator. Tobul forbids welding to the shell or end caps, because heat weakens the metal and the seals.
- Keep the warning label readable. Paint and grime hide it, and the next person needs it.
Raised Loads and Blocking
Hydraulic cylinders and valves leak a little inside. A load held up only by oil will drift down sooner or later, and a broken hose can drop it all at once. Never put any part of your body under a load held up only by hydraulics or air.
- Lower the load to the floor, its stops or its mechanical rest whenever you can.
- If it has to stay up, block it first with the maker's safety prop, pin, bar or cylinder stop, or with cribbing rated for the load.
- Place the block from the side, never from under the load.
- Make sure the block sits square and cannot kick out.
- Only then bleed the pressure, and watch that the block takes the weight.
On construction sites, OSHA 1926.600(a)(3)(i) requires equipment held aloft by slings, hoists or jacks to be blocked or cribbed before anyone works under it, and requires blades, buckets and dump bodies to be fully lowered or blocked during repairs. A jack is for lifting, not for holding.
Air systems hold loads too. A vertical air cylinder, an air balancer or an air-released brake can let a load drop when the air is removed. Trapped air can also drive a cylinder hard the moment a fitting is loosened.
Restarting is a hazard as well. When air or oil comes back after work, a cylinder with one side empty can lunge. Clear everyone from the machine's travel, and use a soft-start valve or reduced pressure if the procedure calls for it.
Compressed Air on People
- Never point compressed air at anyone, and never use it on your skin or clothing. Canada's workplace safety center, CCOHS, warns that air can enter the body through the ears, nose or a small cut, and on rare occasions can cause an air bubble in the blood that leads to coma, paralysis or death.
- Cleaning with air. OSHA 1910.242(b) allows compressed air for cleaning only when it is reduced to less than 30 psi, and then only with effective chip guarding and personal protective equipment. OSHA's enforcement directive says the pressure must stay under 30 psi even when the nozzle is blocked, so use a nozzle built to meet it.
- Eyes and ears. Wear safety glasses for any blowing or air tool work. Exhausts and blowoffs are loud, so keep silencers on valve exhausts and wear hearing protection where it is posted.
- Disconnect before you change a bit or blade on an air tool, and keep the tool secured to its hose.
Heat and Fluid Contact
Oil, pumps, valves and motors run hot. Let them cool, or wear heat-resistant gloves, before you handle them. Read the safety data sheet for the fluid and wear the gloves and eye protection it names. Wash oil off your skin, and change out of oil-soaked clothes.
Common Mistakes
| Mistake | What it costs | Better habit |
|---|---|---|
| Feeling for a leak by hand | Injection injury, possible amputation | Cardboard and a face shield, or shut down |
| Waiting to see if a puncture gets worse | Lost hours of treatment time | Go to the ER now |
| Tightening a fitting under pressure | Thread failure and a spray in the face | Shut down and relieve pressure first |
| Precharging with shop air | Explosion inside the accumulator | Dry nitrogen only, by trained people |
| Working under a load held by oil | Crushing when it drifts or a hose fails | Lower it or block it first |
| Blowing dust off your clothes | Eye injury or air in the body | Use a brush or vacuum |
Check Your Understanding
1. A coworker gets a pinprick on his palm from a weeping hose. It barely bleeds and he wants to finish the job. What do you tell him?
That it may be an injection injury, which is a surgical emergency even when it looks small. He needs to go to an emergency room now, with the fluid's name and safety data sheet, and tell the staff it was a high-pressure injection.
2. A dump truck bed must stay raised while you replace a hydraulic hose. The truck is off and the bed has not moved. Is it safe to go under it?
No. Oil leaks inside the cylinder and valves, and opening the hose removes what is holding it. Set the body prop or blocking first, from the side, then relieve the pressure.
3. The precharge on an accumulator is low, and the nitrogen bottle is empty. Someone suggests topping it off with shop air. What is wrong with that?
Air contains oxygen, which can ignite with oil under pressure and cause an explosion. Only dry nitrogen goes in an accumulator, and the charge is done by trained people with the maker's kit.
4. A clean-up crew uses a blowgun at full header pressure to clear chips off a fixture. What does OSHA require?
For cleaning, OSHA requires air reduced to less than 30 psi, with effective chip guarding and protective equipment. Fit a nozzle that holds dead-end pressure under 30 psi, and keep people out of the path of the chips.
Key Takeaways
- Lockout comes first, and a stopped pump or a zero gauge does not prove a line is empty.
- An injection injury is a surgical emergency, however small it looks.
- Never feel for a leak with any part of your body.
- Restrain and protect hoses, and never exceed the lowest rating in an assembly.
- Treat accumulators as charged, and precharge only with dry nitrogen.
- Block raised loads before you bleed pressure, and never point compressed air at a person.