Skip to content

Framing with Steel Studs

15 min read Training Guide

Read steel stud designations, lay out and fasten track, set studs and deflection track, frame openings and backing, and screw gypsum board to steel the right way.

Table of contents

Walk into almost any office, school, store or hospital under construction and the interior walls are framed in light steel. Steel studs are straight, light, do not rot or burn, and come cut to length. They also behave differently from wood. A thin flange bends away from a screw, a stud screwed to the wrong track can crack the wall when the floor above deflects, and a cut edge will slice through a glove. Framers who learn the differences early hang flatter walls and get fewer cracked joints.

This guide covers nonstructural steel framing: interior partitions and ceilings that carry their own weight and the board, not the building. Load-bearing steel framing is designed by an engineer and is a different job. Member standards come from ASTM C645, installation from ASTM C754 and the maker's instructions, and the drawings and wall types control every project. Fire-rated walls must match their tested assembly exactly.

What You Will Be Able to Do

  • Read a steel stud designation and pick the right member.
  • Lay out and fasten floor and ceiling track.
  • Set studs, including at deflection track, so the wall can move without cracking.
  • Frame door openings, headers and backing.
  • Fasten gypsum board to steel with the right screw and sequence.

Parts of a Steel Wall

Part Shape Job
Track (runner) U-shaped, no lips Holds the studs at floor and ceiling
Stud C-shaped, with lips and punchouts The vertical members
Deflection track Track with deep legs or slots Lets the floor above move without loading the wall
Cold-rolled channel Small, stiff channel Bracing through the punchouts
Flat strap and backing Flat steel or blocking Support for cabinets, grab bars, TVs

Punchouts are holes in the stud web for bracing, conduit and cable. Set every stud the same end up so the punchouts line up across the wall.

Reading the Designation

Steel framing is labeled with a standard code. Take 362S125-18 as an example:

Part Meaning
362 Web depth of 3.62 inches, which is a 3-5/8-inch stud
S Stud. T means track
125 Flange width of 1.25 inches
18 Steel thickness of 18 mils. One mil is 1/1000 of an inch

Common web depths are 1-5/8, 2-1/2, 3-5/8, 4 and 6 inches. Thickness in mils replaces the old gauge numbers. Some drawings still say gauge, and one framing maker's chart lists 43 mils as 18 gauge and 54 mils as 16 gauge. Use the maker's chart for the product you have, because thin members do not convert neatly.

Some studs are made of thinner, higher-strength steel and sold as equivalent to a heavier member. Do not swap one kind for another unless the drawings or the engineer allow it.

Limiting Heights

How tall a wall can be depends on the stud depth, thickness, spacing, and how much the wall is allowed to bend. Makers publish limiting height tables. The limit is written as a fraction of the wall height, such as L/240. A stiffer limit, such as L/360, is often used behind brittle finishes such as tile or plaster, and the drawings or spec name the limit for each wall type. If a wall on your job looks taller than the stud in your hand should go, check the table and ask.

Layout

  1. Snap the floor lines. Snap both edges of the track on the floor from the drawings, and mark door openings, wall ends and corners.
  2. Transfer to the ceiling. Use a plumb laser to transfer the floor line to the ceiling or deck, at both ends and every few feet.
  3. Check the wall type. The drawings tell you the stud size and spacing, whether the wall goes to the deck or stops at the ceiling, whether it is fire or sound rated, and what head detail to use.

Installing Track

  1. Cut and place the floor track. Run it continuous, then cut it out at door openings later, or stop it at each jamb, as your crew does it.
  2. Fasten it. Fasten near each end and along its length at the spacing the drawings or spec give. Many specs call for no more than 24 inches apart. On concrete, use powder-actuated fasteners or concrete screws. On wood, use screws.
  3. Fasten the ceiling track on the transferred line, to the deck, joists or blocking above, the same way.

Warning: OSHA allows only workers trained on that particular powder-actuated tool to operate it (1926.302(e)). Treat it like a firearm: never point it at anyone, keep your hand away from the muzzle, and wear eye and hearing protection.

Setting Studs

  1. Cut studs to length. Measure from the floor track to the ceiling track at each stud location, because floors and decks are not level. Cut the stud short of the full height by the amount the head detail or maker calls for so it slips in without forcing.
  2. Cut safely. Use aviation snips on light members, cutting each flange and then bending and cutting the web, or a chop saw with a metal-cutting blade. A saw throws hot burrs and sparks, so clear combustibles and wear eye protection.
  3. Stand them up. Twist each stud into both tracks, with all open sides facing the same direction, at the spacing on the drawings, usually 16 or 24 inches on center.
  4. Fasten at the bottom. Screw both flanges of each stud to the floor track with pan-head or wafer-head framing screws, or crimp them where the spec allows.
  5. Fasten at the top, unless it is deflection track (below).

Deflection Track

The floor or roof above a wall bends under load. If wall studs are screwed tight to the structure, that movement crushes the wall and cracks the board. Deflection track lets the structure move.

  • Deep-leg (slip) track has long legs. The studs are cut short so there is a gap at the top, and they are not fastened to the track. One major maker requires a row of bracing within 12 inches of the deflection track to keep the studs from rotating.
  • Slotted track has vertical slots in its legs. Studs are screwed through the middle of the slots so the screws can slide up and down. Leave the gap between stud and track that the maker specifies.
  • Gypsum board at the top of the wall is not screwed into the deflection track either, or the board would lock the joint. Follow the head-of-wall detail, and use the listed fire-rated joint system on rated walls.

Openings and Backing

  • Door jambs. Jamb studs are often heavier or doubled, as the spec shows, because doors slam. Hollow metal frames attach with the frame maker's anchors.
  • Headers. A common header is a length of track cut and bent so its ends turn down over the jamb studs, with short cripple studs above at the stud spacing.
  • Backing. Cabinets, handrails, grab bars, TVs and wall-hung fixtures need backing in the wall: steel strap, steel backing plates, or fire-retardant-treated wood where the spec allows. Install it before the board goes on, at heights from the drawings.
  • Bracing. Run cold-rolled channel through the punchouts and clip it to the studs where the drawings show bracing.

Working With Other Trades

  • The electrician installs plastic grommets or bushings in punchouts where cable passes, to protect it from the sharp steel edges, as the electrical code requires. Do not remove them.
  • Do not cut stud flanges or lips to make room for pipes or boxes. A cut flange loses most of the stud's strength. Ask for a different route or added framing.
  • Close a wall only after the rough-ins inside it are inspected and approved.

Hanging Board on Steel

Steel thickness Screw type
Under 0.033 inch Type S, sharp point, fine thread (ASTM C1002)
0.033 to 0.112 inch Type S-12, drill point (ASTM C954)
  • Length. The screw must go through the steel and stick out past it. A common rule is at least 3/8 inch past the steel. For 1/2-inch board on light studs, 1-inch Type S screws are typical, and 5/8-inch board often takes 1-1/4 inch.
  • Sequence. The Gypsum Association says to attach the leading edge of each panel to the open, unsupported edge of the stud flange. When the next panel's edge goes on that same flange, it is fastened near the stiff web side, so the flange does not bend away and the joint stays flat.
  • Placement. Keep screws about 3/8 inch or more from board edges, and drive them so the head dimples the paper without tearing it, just as on wood.

Worked Example: Material for One Wall

A partition is 24 feet long, with 3-5/8-inch studs at 16 inches on center and one 3-foot door opening.

  • Spaces: 24 x 12 / 16 = 18 spaces, so 19 stud locations along the wall.
  • Two or three of those locations fall in the door opening. They become short cripples above the header instead of full studs.
  • Add 2 studs for the door jambs, or 4 if the spec calls for doubled jambs.
  • Track: 24 feet at the floor and 24 at the top = 48 feet. In 10-foot lengths, that is 5 pieces, with offcuts for the header.
  • Remove the 3 feet of floor track across the door opening.

Common Mistakes

Mistake What it costs
Screwing studs to deep-leg deflection track Cracked board and crushed studs when the floor above moves
Studs set with open sides facing different ways Uneven joints and screws that spin off the flange
Punchouts not lined up Bracing and cable cannot run through
Cutting flanges for pipes A weak stud and a bulging wall
Wrong screw for the steel thickness Screws that will not penetrate or that strip
No backing for a grab bar Opening a finished wall later
Substituting studs on a rated wall A wall that no longer matches its listing

Check Your Understanding

1. The drawings call for 600S162-43 studs. What are they?

6-inch web studs with 1-5/8-inch flanges, 43 mils thick.

2. A coworker screws every stud to the top track in a wall that uses deep-leg deflection track. What will happen?

When the floor above deflects, it pushes down on the studs and the board, cracking joints and bending studs. Studs in deep-leg track must stay unfastened at the top.

3. You are hanging board on 33-mil studs, and the screws spin without biting. What do you check?

The screw type. At 0.033 inch and thicker, use Type S-12 drill-point screws, and check the screws reach past the steel.

4. A plumber wants to notch the flanges of three studs to fit a drain. What do you say?

Do not cut the flanges. Ask your lead for another route or added framing.

Key Takeaways

  • Steel designations give web depth, member type, flange width and thickness in mils.
  • Check limiting heights, and never swap members without approval.
  • Fasten track near the ends and at the spec spacing, and only use a powder-actuated tool if you are trained on it.
  • Set all studs open side the same way with punchouts lined up.
  • Never fasten studs or board into deep-leg deflection track.
  • Use Type S screws on light steel and S-12 on heavier steel, long enough to pass through it.