Skip to content

How Pneumatic Systems Work

15 min read Training Guide

Follow compressed air from the compressor to the cylinder, set a filter-regulator-lubricator, read valve names and port numbers, and work out cylinder force and air use.

Table of contents

Pneumatics does work with compressed air. Air runs clamps, grippers, cylinders, air tools, blowoffs, vacuum cups and the actuators on process valves. Air is clean, fast and easy to pipe around a building, and a leak does not leave oil on the floor. It is also one of the most expensive utilities in a plant to make, and it behaves differently from oil because it squeezes. Knowing where the air comes from, how it is cleaned and how valves route it lets you keep machines cycling and spot trouble early.

What You Will Be Able to Do

  • Follow air from the compressor to a machine and name each part along the way.
  • Explain why compressed air carries water and how the system removes it.
  • Set a filter, regulator and lubricator correctly.
  • Read a pneumatic valve's name and port numbers.
  • Work out a cylinder's force and how much air it uses.

Air Is Not Oil

Feature Pneumatics Hydraulics
Typical pressure Around 80 to 120 psi plant air Often thousands of psi
Squeezes? Yes, a lot Barely
Return path Exhausts to the room Returns to a tank
Force for its size Low High
Holding mid-stroke Poor, it springs Good

Because air squeezes, it stores energy like a spring. That gives fast, cushioned motion, but it also means a cylinder can lunge when trapped air is released or when air comes back on.

Gauge and absolute pressure. A gauge reads 0 psi at normal air pressure, which is about 14.7 psi at sea level. Gauge readings are written psig, and readings that include the atmosphere are written psia. At 100 psig, air is squeezed to about (100 + 14.7) / 14.7 = 7.8 times its normal volume. That ratio matters when you work out air use.

From the Compressor to the Machine

Air passes through these parts on its way to a cylinder:

  1. Intake filter. Keeps dust out of the compressor.
  2. Compressor. Piston (reciprocating) compressors suit smaller or stop-and-start demand. Rotary screw compressors suit steady plant demand. Some are oil-flooded inside, and some are oil-free.
  3. Aftercooler. Air leaves the compressor hot. Cooling it right away condenses much of its water so a drain can remove it.
  4. Receiver tank. Stores air so the compressor does not chase every short burst of demand. It has a pressure relief valve and a drain at the bottom.
  5. Dryer. Removes the water vapor still left in the air (see below).
  6. Main filters. Catch oil aerosol and particles.
  7. Header. The main pipe through the building, often a loop so air can reach a machine from two directions.
  8. Branch and drop lines. Take air down to each machine. Good practice takes branches off the top of the header, so water running along the bottom of the pipe does not fall into them, and ends each drop with a drain leg below the takeoff.
  9. Filter, regulator and lubricator (FRL) at the machine, then the valves and actuators.

Most plant air systems run somewhere around 80 to 120 psi in the header, and the regulator at each machine brings it down to what that machine needs.

Water in Compressed Air

Outdoor air always carries water vapor. When a compressor squeezes 7 or 8 cubic feet of air into one, the water in all of it is squeezed in too. As that air cools, the water condenses. If it is not removed, it rusts pipes, washes grease out of valves and cylinders, and freezes in lines that run through cold spaces.

Pressure dew point is the temperature at which water starts to condense out of air at its working pressure. If any pipe gets colder than the pressure dew point, water forms in that pipe.

Dryer Typical pressure dew point Where it fits
Refrigerated About 35 to 39°F Indoor piping that stays warm
Desiccant (twin tower) About -40°F Lines outdoors in winter, instrument air

Those typical figures come from U.S. Department of Energy compressed air training. Your dryer's data plate gives its own rating.

Drains matter as much as dryers. Water left in a receiver or a filter bowl evaporates back into the dry air downstream. Manual drains get forgotten, and timer drains waste air. DOE training recommends level-activated drains, which open only when water is there. A drain stuck shut, or a dryer left on bypass after service, puts water at every machine.

The Filter, Regulator and Lubricator

The FRL sits where air enters a machine, in that order in the direction of flow: filter first, regulator second, lubricator last. A lockable shutoff valve that vents the downstream air is often mounted at its inlet.

Filter. Spins water drops out and traps particles in its element. Drain the bowl before water reaches the baffle. If the bowl is clear plastic, keep its metal guard on, and keep solvents and aerosol sprays off it, because some chemicals weaken the plastic.

Regulator. Holds a steady lower pressure downstream no matter how the header swings. To set it:

  1. Pull the knob out to unlock it, if it has a lock.
  2. Turn it down below the pressure you want.
  3. Turn it up slowly until the gauge reads the setting on the machine's sheet.
  4. Cycle the machine, recheck the gauge, and lock the knob.

Setting it by coming up from below gives a more accurate setting than coming down from above.

Lubricator. Adds a fine oil mist for parts that need it. Many valves and cylinders sold today are greased for life and meant to run on unlubricated air. Makers such as Festo and SMC warn that oiled air washes that factory grease out, so once a part has run on oiled air, it has to stay on oiled air. Check the maker's data before you add or remove a lubricator, and use only the oil the maker names.

Valves

Valve Names

A valve name gives two numbers: ports, then positions.

Name Ports Positions Common use
2/2 2 2 Simple on and off
3/2 3 2 Single-acting cylinder, or a supply valve that vents
5/2 5 2 Double-acting cylinder
5/3 5 3 Double-acting cylinder that must stop or float mid-stroke

A 3/2 valve can be normally closed, passing no air until it is shifted, or normally open.

Port Numbers

Pneumatic valves use port numbers set out in ISO 11727.

Number Job
1 Supply in
2 and 4 Outlets to the actuator
3 and 5 Exhausts
12 and 14 Pilot signals

Older valves may be lettered instead: P for supply, A and B for outlets, and R and S, or EA and EB, for exhausts.

A signal at 14 connects 1 to 4. A signal at 12 connects 1 to 2. Check the valve body or the maker's sheet, because the label there is the final word.

How the Valve Shifts, and What Happens When Power Fails

  • Single solenoid, spring return. Energize the coil and the valve shifts. Lose power and the spring puts it back. The machine goes to a known position.
  • Double solenoid. One coil shifts it each way, and it stays where it was last put. Lose power and it holds that position, so a cylinder that was extending keeps extending.
  • 5/3 centers. A closed center traps air in both ends of the cylinder. An exhaust center vents both ends, so the cylinder can be pushed by hand. A pressure center feeds both ends.

Swapping a double-solenoid valve for a single-solenoid valve, or changing the center type, changes what the machine does when power is lost or an emergency stop is pressed. Only make that swap with the machine's documents and your lead's approval.

Cylinders, Force and Speed

Force

Force = pressure x area, and area = 0.785 x bore x bore. On the rod side, subtract the rod's area.

Worked example: A cylinder has a 2-inch bore and a 5/8-inch rod at 80 psi.

  1. Piston area = 0.785 x 2 x 2 = 3.14 square inches.
  2. Extending force = 3.14 x 80 = about 251 pounds.
  3. Rod area = 0.785 x 0.625 x 0.625 = 0.31 square inches, so the rod side is 2.83 square inches.
  4. Retracting force = 2.83 x 80 = about 226 pounds.

Friction in the seals takes some of that, and pressure at the cylinder drops while it moves, so the real force is lower than the math. That is why cylinders are sized with a margin over the load.

Speed

Air cylinder speed is set with flow controls, which are needle valves with a built-in check. On a double-acting cylinder, the usual setup is meter-out: the flow control restricts air leaving the cylinder and lets air in freely. The piston then moves against a cushion of air and runs smoother than it would if you choked the air going in. Single-acting cylinders are metered in. Cushions at the ends of the stroke slow the piston so it does not slam.

Air Use

A cylinder uses its swept volume, multiplied by the pressure ratio.

Worked example: The same 2-inch cylinder has a 6-inch stroke, runs at 80 psig, and cycles 20 times a minute.

  1. Extending volume = 3.14 x 6 = 18.8 cubic inches.
  2. Retracting volume = 2.83 x 6 = 17.0 cubic inches.
  3. One full cycle = 35.8 cubic inches of air at 80 psig.
  4. Pressure ratio = (80 + 14.7) / 14.7 = 6.44.
  5. Free air each cycle = 35.8 x 6.44 = 231 cubic inches.
  6. Each minute = 231 x 20 = 4,620 cubic inches, and 4,620 / 1,728 = about 2.7 cubic feet a minute.

That leaves out the air in the tubing between the valve and the cylinder, which is one reason to mount valves close to the cylinders they run.

Leaks Cost Money All Day

A leak hisses through nights and weekends whenever the compressor runs. The Compressed Air Challenge, a DOE partner program, says a well-maintained system should lose less than 10 percent of its compressor's output to leaks, and that poorly maintained systems can lose 20 to 30 percent. Tag leaks you hear on your rounds so they get fixed.

Common Mistakes

Mistake What it costs Better habit
Turning up the regulator for a slow cylinder Harder hits, more air, the real fault stays Check flow controls, tubing and the valve
Ignoring drains Water in every valve and cylinder Check drains and the dryer on every round
Adding a lubricator to a dry-air machine Washes out factory grease Follow the maker's lubrication data
Setting a regulator from above Setting drifts Come up to the setting from below
Swapping valve types to get a machine running Changes power-loss behavior Match the part number
Long tubing from valve to cylinder Wasted air and slow response Mount valves near the cylinders

Check Your Understanding

1. A clamp cylinder has a 3-inch bore and runs at 60 psi. How hard can it push?

Area = 0.785 x 3 x 3 = 7.07 square inches. Force = 7.07 x 60 = about 424 pounds, less a little for seal friction.

2. Air tools on one line spit water every humid afternoon, though the plant has a refrigerated dryer. Name two things to check.

Check whether the drains at the receiver and dryer work, and whether the dryer is running and not on bypass. Also check whether that line runs anywhere colder than the dryer's pressure dew point, such as outdoors or through an unheated space.

3. Power fails while a cylinder is halfway out. Its valve is a 5/2 double solenoid. What does the cylinder do?

The valve stays where it was last shifted, so air keeps flowing to the same side. The cylinder keeps extending until the end of its stroke or until the air pressure is gone.

4. On a 5/2 valve, which port connects to the supply, and which ports should you find a silencer on?

Port 1 is the supply. Ports 3 and 5 are the exhausts, which usually carry silencers.

Key Takeaways

  • Air squeezes, so it stores energy and can make a cylinder lunge.
  • Air passes through an aftercooler, receiver, dryer and filters before the header, then the FRL at each machine.
  • Water is the main thing to remove, and working drains matter as much as the dryer.
  • Valve names give ports, then positions, and ports are numbered 1 for supply, 2 and 4 for outlets, 3 and 5 for exhausts.
  • Single-solenoid valves return on power loss, and double-solenoid valves hold their last position.
  • Force = pressure x area, and air use = swept volume x pressure ratio.