Skip to content

Installing a New-Construction Window

15 min read Training Guide

Check a window against egress, safety glass and fall rules, then set a nail-fin window plumb, level and square, fasten it per the maker, and prove it operates before it is flashed in.

Table of contents

A new-construction window has a nailing fin, a flat flange around the frame that is fastened to the wall sheathing. It goes into a framed rough opening before the siding, usually after the weather barrier is on. Setting it is quick. Setting it so the sashes slide, the locks line up, the frame is not bowed and the inspector signs off takes care at every step.

This guide covers checking the window, setting it, fastening it and testing it. The flashing that ties it into the weather barrier is a separate step with its own order, and it only works on a window that is set right. The window maker's installation instructions control fastener type, spacing, shimming and sealant, and they decide the warranty. Read them for each product, since makers disagree on several points.

What You Will Be Able to Do

  • Check a window against the egress, safety glass and window fall rules for its location.
  • Check a rough opening for size, level, plumb and square.
  • Set a nailing-fin window level, plumb and square, with shims where the maker allows them.
  • Fasten the fin without bending it or locking the frame in a bowed shape.
  • Test operation and fix a window that binds before it is flashed and trimmed.

Check the Window for Its Location

Wrong windows are expensive to discover after they are in. Check each one against the room it goes in. These rules come from the International Residential Code. Your adopted edition and local amendments win.

Bedrooms and Basements: Egress

Every sleeping room, and a basement or habitable attic, needs an emergency escape and rescue opening, usually a window.

Requirement Minimum or maximum
Net clear opening 5.7 square feet, or 5.0 square feet at grade floor or below grade
Net clear height 24 inches
Net clear width 20 inches
Sill height No more than 44 inches above the floor

Net clear opening is the actual open space when the sash is opened normally from inside, not the size of the frame. The window's spec sheet lists it. The window must open from inside without keys, tools or special knowledge.

Worked Example: Does This Window Meet Egress?

A second-floor bedroom gets a double-hung window with a net clear opening of 32 inches wide by 24 inches high.

  • Area: 32 x 24 = 768 square inches. 768 / 144 = 5.33 square feet.
  • It meets the 24-inch height and 20-inch width minimums.
  • It does not meet 5.7 square feet, so it fails as the bedroom's escape opening.

A casement of the same frame size opens almost its whole sash width, so it often passes where a double-hung fails. If the width is only 20 inches, the height must be at least 5.7 x 144 / 20 = 41 inches.

Safety Glazing

Glass in certain places must be safety glazing, such as tempered or laminated glass, because people are likely to fall into it. Common hazardous locations for windows:

  • Large, low windows where all four are true: a single pane over 9 square feet, its bottom edge under 18 inches above the floor, its top edge over 36 inches above the floor, and a walking surface within 36 inches of it.
  • Next to a door, within 24 inches of the door edge, with the bottom edge under 60 inches above the floor.
  • At tubs and showers, with the bottom edge under 60 inches above the standing surface.
  • Next to stairs and landings, with the bottom edge under 36 inches above the walking surface, and near the bottom landing.

Each safety glazing pane carries a permanent label. Check for it before the window goes in. Leave the labels and stickers in place until the inspector has seen them, unless told otherwise.

Window Fall Protection

Children fall from open windows. Where an operable window's sill is less than 24 inches above the floor and more than 72 inches above the ground outside, the code requires that it not open far enough to pass a 4-inch ball, or that it have a fall prevention or opening control device meeting ASTM F2090. An opening control device on an egress window must still let the window open fully for escape.

Check the Rough Opening

  1. Size. Compare it with the maker's listed rough opening for that window, often slightly larger than the frame on each side.
  2. Sill level. The rough sill must be level. A sill that slopes puts the whole window out of level.
  3. Sides plumb, checked with a level on both jack studs.
  4. Square. Measure both diagonals. They should match.
  5. Flat. The sheathing around the opening must be flat so the fin can lie flat on it.

Fix the opening now. Shims fix small errors at the window, but they do not fix a sill that is 1/2 inch out.

Working Safely at Window Openings

Warning: An open window opening on an upper floor is a fall hazard. OSHA requires guardrails, a safety net or a personal fall arrest system when a wall opening's outside bottom edge is 6 feet or more above the level below and its inside bottom edge is less than 39 inches above the floor you are standing on. Do not lean out to reach the fin. Set it from a scaffold or a properly set ladder outside, with a helper inside.

Windows are heavy and catch wind like a sail. Large units and mulled groups of windows take two or more people, and some need a lift.

Set the Window

The sill pan or sill flashing goes in first, with sealant behind the side and head fins but not along the bottom fin, so water in the pan can drain out. Then:

  1. Inspect the window. Check for damage, check that the size and hand match the plan, and leave the shipping blocks and sash locks as the maker says until it is fastened.
  2. Set the bottom first. With a helper inside, tip the window in from outside, set the bottom fin against the wall at the sill, and swing the top in.
  3. Shim if the maker allows it. Many makers call for shims under the jambs at the sill corners, and under any mullion, to set it level. Do not shim the middle of the sill unless the instructions show it, since that can bow the sill up.
  4. Center it in the opening side to side.
  5. Tack one top corner loosely so the window cannot fall out.
  6. Level the sill. Use the shims to adjust.
  7. Plumb the sides. Check the jambs from inside or outside with a level.
  8. Square the frame. Measure both diagonals of the frame. Adjust until they match.
  9. Check the sash. Close and lock it. Look at the gap between the sash and the frame. It should be even.

Fasten the Fin

Follow the maker's fastener and spacing, which vary.

  • Fastener type. Often galvanized roofing nails or screws, long enough to reach solid framing through the sheathing. One maker calls for nails at least 1-3/4 inches long, and another specifies a minimum head size.
  • Spacing. One major maker calls for a fastener in every other hole, about every 8 inches, and no more than 4 inches from each corner. Others use different spacing.
  • Slots. Vinyl windows expand and contract. Drive fasteners in the center of slotted holes so the frame can move. Some makers want the fastener head left just short of tight. Others want it snug. Do what your instructions say.
  • The head fin. Some makers say to fasten the top fin, and others say to leave it loose or fasten it only in slots, so a sagging header cannot crush the frame.
  • Do not bend the fin. A nail driven at an angle or a hammer that strikes the fin bends it, and a bent fin will not seal under the flashing tape.

Fasten the bottom corners first, check level and square again, then fasten the sides from bottom to top, checking as you go.

Test Before You Flash

Once the fin is fastened and before flashing tape goes on:

  1. Open and close every sash fully. It should slide or swing without binding.
  2. Lock every lock. Locks that need force to engage mean the frame is out of square or bowed.
  3. Measure the width between jambs inside the frame at the top, middle and bottom. A smaller measurement in the middle means the jambs are bowed in.
  4. Check the screen fits.
Symptom Likely cause Fix
Sash binds in the middle Jambs bowed in by fasteners or shims Back out the side fasteners, straighten, refasten
Lock will not line up Frame out of square Check the diagonals, and reset
Sash gap wider at the top on one side Window out of plumb Reshim the sill corner, and refasten
Sill bowed up Shim under the middle of the sill Remove it

After the window passes, flash the jambs and head in shingle order and leave the bottom fin unsealed for drainage.

Inside the Opening

  • Remove sill shims after fastening if the maker says to. Some want the window hanging on its fins, not on shims.
  • Air seal the gap between the frame and the framing with low-expansion foam made for windows, or backer rod and sealant. Standard expanding foam can bow the frame.
  • Test the sash again after the foam cures.
  • Protect the window from paint, drywall mud and stucco. Leave the protective film on until the trades are done, but remove it within the time the maker allows, since film left in the sun can bake on.

Common Mistakes

Mistake What it costs
Ordering a bedroom window that fails egress A failed inspection and a new window
Plain glass in a hazardous location A failed inspection, or a serious cut
Leaning out of an upper-floor opening A fall
Shim under the middle of the sill A bowed sill and sash that will not close
Fasteners driven tight at the ends of slots A vinyl frame that buckles in summer
Flashing before testing operation Tearing off tape to reset a bad window
Standard expanding foam A bowed frame and sash that sticks

Check Your Understanding

1. A casement for a bedroom has a net clear opening of 21 inches wide by 38 inches high. Does it meet egress on a second floor?

21 x 38 = 798 square inches, which is 5.54 square feet. That is under 5.7, so it fails, even though it meets the 20-inch width and 24-inch height minimums.

2. A 4 by 5 foot picture window will go in a living room, 12 inches above the floor, beside a walkway. Its top edge is at 72 inches. Does it need safety glazing?

Yes. The pane is 20 square feet, which is over 9. The bottom edge is under 18 inches, the top edge is over 36 inches, and a walking surface is within 36 inches. All four conditions are met.

3. After you fasten the fin, the sash binds halfway up. What do you check?

Measure the width between the jambs at the top, middle and bottom. If the middle is narrow, the jambs are bowed in. Back out the side fasteners, straighten the jambs, and refasten.

4. You are on the second floor, and the opening's sill is 30 inches above the floor. What protection do you need before working at it?

The inside edge is under 39 inches and the outside drop is more than 6 feet, so you need a guardrail, safety net or personal fall arrest system.

Key Takeaways

  • Check every window against egress, safety glazing and window fall rules before it goes in.
  • Fix the rough opening first: level sill, plumb sides, square corners.
  • Set it level, plumb and square, shimming only where the maker shows.
  • Fasten the fin with the maker's fasteners and spacing, in the center of the slots, without bending it.
  • Test every sash and lock before flashing, and use low-expansion foam inside.