Laminate looks like wood and installs like click vinyl, but it behaves differently. Its core is high-density fiberboard (HDF), a wood product. It grows and shrinks with humidity, it swells for good when water gets into it, and its hard face chips if you hit it wrong. A laminate floor lasts when it has a dry base, the right underlayment, enough room to move, and joints that were closed without damage.

Every laminate line has its own installation sheet, and the sheet controls the expansion gap, the longest run, acclimation, moisture limits and which rooms the floor can go in. The numbers below come from published instructions for one widely sold laminate, as examples. Your product's sheet wins wherever it says something different.

What You Will Be Able to Do

  • Tell whether a laminate product is allowed in a given room.
  • Choose an underlayment and install a vapor barrier over concrete.
  • Plan expansion gaps and the breaks a long or narrow area needs.
  • Close joints with a tapping block and pull bar without damaging them.
  • Recognize the causes of swelling, peaking and gapping.

What Laminate Is

A laminate plank has four layers: a clear wear layer, a printed image, the HDF core, and a backing that balances the plank. Many boxes list an AC rating, a wear class running from AC1 for light home use up to AC5 for heavy commercial use. Higher numbers resist wear better.

Some lines are sold as water-resistant. They have coatings or sealed edges that hold off spills for a time. That is not the same as waterproof, and the sheet says what the rating covers.

Where Laminate Can Go

Room or condition What to check
Living areas, bedrooms, halls Usually fine above, on or below grade
Kitchens Allowed by many products. Wipe spills fast
Full baths and laundry rooms Only if the product is rated for it, often with sealed edges
Rooms with a floor drain or sump pump Excluded by many makers
Basements Allowed by many with a vapor barrier and a passing moisture test
Climate One product requires 35 to 65 percent relative humidity and 60 to 85°F for the life of the floor

The climate row matters most. A laminate floor in a house with no humidity control can open gaps every winter and peak every summer.

Moisture Limits

Test before you install, using the method the maker names. One product sets these limits:

  • Concrete: no more than 5 pounds per 1,000 square feet per 24 hours by calcium chloride test, or under 80 percent RH by in-slab probe.
  • Wood subfloor: 12 percent moisture content or less.

Other products use other limits. Write yours down and compare.

Underlayment and Vapor Barrier

Underlayment is the thin layer between the subfloor and a floating floor. It cushions the floor, smooths tiny bumps and quiets footsteps.

Type Use
Plain foam Over wood subfloors, where the maker allows
Foam with a film layer Combines underlayment and vapor barrier, seams taped
Acoustic (cork, felt, rubber) Apartments and condos with sound rules
Pad attached to the plank No added pad unless the maker allows one

Do not stack two underlayments unless the sheet allows it. Too much cushion lets joints flex and break.

Many condo associations require an underlayment with a minimum sound rating. Check before you order.

Vapor Barrier over Concrete

Concrete always gives off some moisture. A vapor barrier keeps it out of the HDF.

  1. Use the film the maker names. One calls for 6-mil polyethylene.
  2. Roll it out across the floor.
  3. Overlap the seams by at least 8 inches and tape them.
  4. Run the film all the way to the walls, or slightly up them if the sheet says to, so the base hides the edge.
  5. Patch any tears before the floor goes on.

Do not add a separate film under an underlayment that already has a built-in barrier, unless the sheet tells you to. Over a wood subfloor, follow the sheet. Many call for underlayment only.

Expansion Gaps and Breaks

One product calls for a 3/8-inch gap at all walls, pipes and fixed objects. Others call for 1/4 inch. Use spacers, and measure the gap after the joints are closed, since closing a joint can push the row toward the wall.

The same product needs a T-molding break:

  • In any doorway 4 feet wide or less.
  • In any room 40 feet or more in length or width.

Worked Example: Planning Breaks

A family room is 22 feet by 26 feet. It opens through a 32-inch doorway into a hallway that runs 44 feet to the bedrooms. The product's limits are 40 feet and 4-foot doorways.

  • Family room. 22 and 26 feet are both under 40, so no break is needed inside the room.
  • Doorway. 32 inches is under 4 feet, so it needs a T-molding.
  • Hallway. 44 feet is over 40, so the hall needs a break. Place it where the hall meets a bedroom doorway, which also needs a T-molding under this rule.

Breaks also go wherever the floor would be pinned between two fixed points, and at transitions to other flooring.

Cutting Laminate

  • Use a carbide blade. The wear layer is very hard and dulls steel blades fast.
  • Cut face up on a table saw, miter saw or hand saw, and face down on a circular saw or jigsaw, so chipping lands on the back.
  • Cutting HDF makes fine wood dust. Use dust collection or cut outdoors, and wear the respirator your employer's plan calls for.
  • A laminate shear makes crosscuts with no dust, but it cannot rip planks.

Installing the Floor

A floating floor follows the same order for any click product. These are the steps where laminate differs.

  1. Undercut door frames and casings. One product wants the plank to slide at least 1/4 inch under the frame, with its full expansion gap hidden behind it.
  2. Prepare the first row. Some makers want the tongue cut off the wall side of the first row. Scribe the first row to the wall if the wall is not straight.
  3. Mix cartons. Pull from several cartons at once so shades and patterns spread out.
  4. Follow the length rules. One product wants the first piece of each row at least 8 inches long and at least 6 inches between end joints in neighboring rows.
  5. Angle in the long side. Most laminates lock by raising the plank to a low angle, pushing the tongue into the groove, and rotating down. Many lock the short end first, then lift the outer edge an inch and push the long side home.
  6. Tap only where the sheet says. If you tap, use a tapping block made for the product, place it at least 8 inches from either end of the plank, and tap lightly along the joint. Uneven or hard tapping breaks the lock.
  7. Close the last row with a pull bar. Hook it over the plank's edge and tap the bar, working evenly along the length.
  8. Fit pipes and fixed objects with the same gap as the walls.

Where you cannot angle a plank in, such as under a door frame or at a heat register box, some makers allow cutting off the locking lip and gluing that joint. Use the method and glue the sheet names.

Warning: Do not glue, nail or screw a floating laminate floor to the subfloor, and do not let cabinets, islands or heavy built-ins sit on it. A pinned floor cannot move, and it will buckle.

Wet Areas

If a product is rated for bathrooms, the sheet may call for sealing the perimeter gap and pipe holes with 100 percent silicone before trim goes on. Skipping that step lets water reach the core from the edges, which is where laminate swells first.

Handing Over the Floor

Tell the owner how laminate is cleaned. Most makers forbid wet mopping and steam mops, and say to wipe up spills right away. Felt pads go under furniture legs. Chairs need soft casters.

Fixing Problems

Symptom Likely cause Fix
Swollen, raised edges Water reached the core Find the source, replace the planks
Peaking at doorways No break, or the floor is pinned Add the break, free the pin point
Gaps every winter Dry air below the product's range Humidify, reseat joints
Floor bounces or creaks Dip in the subfloor, or doubled pad Patch the dip, use one underlayment
Chipped corners Hitting plank edges directly Use the tapping block and pull bar
Lock lip broken Too much force Replace the plank

Common Mistakes

Mistake What it costs
Laying laminate in a room with a floor drain Swelling and a voided warranty
Skipping the poly film on concrete Moisture damage from below
Stacking a second pad under attached pad Flexing joints that break
Measuring the gap before closing the joint A floor tight against the wall
Ignoring the 40-foot or doorway rule Peaking across a doorway
Wet mopping at handover Edges that swell within months

Working Safely

  • Wear knee pads, and safety glasses when cutting or tapping.
  • Use a dust-collecting saw or cut outdoors, and follow your respirator plan.
  • Keep fingers clear of the strike zone when using a pull bar.
  • Carry cartons close to your body, one at a time.

Check Your Understanding

1. A customer wants laminate in a basement laundry room with a floor drain. What do you say?

Many makers exclude rooms with floor drains, and laminate swells if water reaches the core. Suggest a product rated for wet areas, such as vinyl or tile.

2. A new laminate floor will float over a basement slab. What must go down first?

The vapor barrier the maker calls for, such as 6-mil poly with seams overlapped at least 8 inches, unless the underlayment has an approved built-in barrier.

3. A hall runs 46 feet. The product's limit is 40 feet. What do you do?

Plan a T-molding break, usually at a doorway along the hall, so neither section runs more than 40 feet.

4. A helper is tapping the end of a plank with a hammer and a scrap block, and the corners keep chipping. What do you change?

Use the maker's tapping block on the joint, not on the face edge, tap lightly and evenly, and use a pull bar at the walls.

5. You set spacers at 3/8 inch, close each long joint, and find the planks now touch the spacers hard. Is the gap still right?

Measure it again. Closing joints can push the row toward the wall. The gap must be 3/8 inch after the joints are closed.

Key Takeaways

  • Laminate's HDF core swells for good when wet, so room choice and moisture tests come first.
  • Use the underlayment the maker allows, and one vapor barrier over concrete with overlapped, taped seams.
  • The sheet sets the gap, run length and doorway breaks. One product uses 3/8 inch, 40 feet and 4-foot doorways.
  • Close joints with a tapping block and pull bar, lightly and evenly.
  • Never pin a floating floor, and teach the owner not to wet mop it.