Installing Metal Roofing

15 min read Training Guide

Choose between exposed-fastener and standing-seam panels, meet the slope rules, plan for thermal movement, cut and fasten panels without causing rust, and flash trim, ridges and pipes.

Table of contents

A metal roof can last for decades, but it is less forgiving of shortcuts than shingles. Metal grows and shrinks with every sunny day and cold night, so it has to be allowed to move. Its coating is what stops rust, so cutting it the wrong way or leaving steel filings on it starts rust on day one. And a long panel in a gust of wind can throw a person off a roof. Metal panel work rewards planning, square starts and the right tools.

This guide covers metal roof panels on residential and light commercial steep-slope roofs. Panel makers publish detailed instructions for each profile, including fastener spacing, clip spacing, trim and sealant locations, and following them is what keeps the panels on in wind and keeps the warranty. The 2021 International Residential Code (IRC) covers metal roof panels in Section R905.10.

What You Will Be Able to Do

  • Tell exposed-fastener panels from standing-seam panels and know where each is allowed.
  • Calculate thermal movement and explain how each system handles it.
  • Start a roof square and keep panels from fanning.
  • Cut and fasten panels without damaging the coating or the seal.
  • Avoid the metal and material contacts that cause corrosion.

Panel Types

Type How it attaches What to know
Exposed-fastener (through-fastened) Screws with rubber washers through the panel into the deck or purlins Lower cost, faster. Hundreds of holes to keep sealed
Standing seam Hidden clips under raised seams, no holes through the panel field Handles movement better, lower slopes allowed
Metal shingles Interlocking pieces Installed like a specialty shingle

Common exposed-fastener profiles include corrugated, R-panel and 5V crimp. Standing-seam panels are either snap-lock, where the seams click together, or mechanically seamed, where a seaming tool folds them closed.

Slope Rules

The IRC sets minimum slopes for metal roof panels (R905.10.2):

Panel seams Minimum slope
Lapped, no lap sealant 3:12
Lapped, with lap sealant per the maker 1/2:12
Standing seam 1/4:12

Panel makers often set a higher minimum for a given profile, and their number wins when it is higher.

Deck and Underlayment

  • The IRC allows metal panels on solid or spaced sheathing, unless the panel is designed for spaced supports such as purlins (R905.10.1).
  • Underlayment follows the code's underlayment rules. Metal gets very hot in the sun, so a self-adhering membrane under it must be rated for high temperature. Check the label.
  • Over old shingles. A recover is allowed only where the code and the panel maker both allow it. One case the IRC names is a standing-seam system designed to carry its loads to the structure without relying on the old roof. Many makers require a slip sheet or framing over shingles.

Metals and Coatings

Material What to know
Galvanized steel Zinc coating. The IRC lists G90 for metal roof coverings
Aluminum-zinc coated steel Often sold under trade names. Good corrosion resistance, sensitive to some contacts
Painted steel Paint over a metallic coating. Scratches let rust start
Aluminum Light, does not rust, moves about twice as much as steel
Copper Long-lived, costly, attacks other metals downhill

Keep incompatible materials apart. The Metal Construction Association warns that copper, pressure-treated wood and HVAC coil cleaners are highly corrosive to metal roofs. Do not let water run off copper, a lead pipe boot or a copper-treated wood surface onto steel panels. Remove old lead and copper flashings on a reroof, and use pipe boots and fasteners the panel maker approves.

Fasteners. Use the panel maker's fasteners. If there are no maker's instructions, the IRC calls for galvanized fasteners on steel roofs, copper-alloy or 300-series stainless on copper roofs, and allows stainless on any metal roof (R905.10.4).

Thermal Movement

Every metal grows when it heats and shrinks when it cools. A long panel moves a lot.

Worked example. A steel panel is 30 feet long, or 360 inches. Its surface temperature swings 150°F between a winter night and a summer afternoon. Steel grows about 0.0000065 inch per inch for each degree F.

  • Steel: 360 x 0.0000065 x 150 = 0.35 inch, about 3/8 inch.
  • The same panel in aluminum, at about 0.0000128: 360 x 0.0000128 x 150 = 0.69 inch, almost 3/4 inch.

That movement has to go somewhere.

  • Standing seam clips let the panel slide. Some clips are fixed in one spot and the rest float, so the panel grows away from the fixed point. Put fixed clips where the maker says, and never screw through a floating panel to "stop a rattle."
  • Exposed-fastener panels flex between screws. Over the years, movement can wallow out holes and loosen screws. Makers limit panel lengths and set screw locations for this reason.

Cutting

Cut panels in a way that shears the metal, not one that grinds or burns it.

  • Use: hand snips, power shears, nibblers, or a saw and blade the panel maker approves.
  • Do not use: abrasive cutoff wheels or other hot cutting. They burn the coating at the edge and throw hot steel bits that embed in the paint and rust.
  • Cut on the ground, away from stacked panels, so filings do not land on them.
  • Sweep up filings, called swarf, from the roof the same day. Steel filings left on a panel rust and stain it, and enough of them can rust through.

Warning: Cut panel edges are as sharp as knives. Wear cut-resistant gloves, sleeves and safety glasses, and hearing protection with power shears or saws.

Installing Exposed-Fastener Panels

  1. Check the roof. Measure both diagonals of each roof plane and check that the eave is straight. A roof that is out of square makes panels walk off line.
  2. Install eave trim and closures. Set the eave trim, then the foam or metal closures that fill the panel ribs at the eave, with sealant tape where the maker shows. Closures keep out wind-driven rain, insects and birds.
  3. Set the first panel square. Line it up square to the eave, not to the rake, with the overhang at the eave the maker specifies. Start at the end the maker says. Many start at the end away from the prevailing wind so side laps face away from it.
  4. Fasten in the maker's pattern. Screws go where the maker shows, usually in the flat beside the ribs or on top of the ribs, at each support line.
  5. Drive screws right. Drive each screw straight until the rubber washer is snug and just slightly compressed. An overdriven screw squashes the washer out and splits it. An underdriven screw leaves a gap. A crooked screw seals only on one side. All three leak.
  6. Lap and stitch. Lap each panel over the last in the direction the maker shows, with sealant if the slope or the maker requires it, and fasten the side lap with stitch screws where shown.
  7. Check for fanning. Every few panels, measure from the last panel's edge to the end of the roof at both the eave and the ridge. If the numbers differ, the panels are fanning out of square. Correct it a little at a time, as the maker allows, before it gets worse.

Installing Standing-Seam Panels

  1. Install eave trim or a cleat for the panel ends to hook onto.
  2. Set the first panel square to the eave.
  3. Fasten clips along the panel's edge at the maker's spacing. The spacing is often closer near edges, corners and the ridge, where wind uplift is highest.
  4. Set the next panel's seam over the first panel's leg and the clips. Snap it closed, or crimp it and run the seaming tool along it, as that profile requires.
  5. At the eave and ridge, hem or fold panel ends as the maker details show.

Trim, Ridges and Penetrations

  • Rakes. Rake trim covers the panel edge and turns down over the fascia.
  • Ridges. A ridge cap goes over closures fastened to the panels. On vented ridges, use the maker's vented closure.
  • Walls. Sidewall and endwall flashings lap over the panels with closures underneath, and the wall's weather barrier and siding lap over the flashing.
  • Valleys. Use a valley pan with the edges the maker specifies, and keep fasteners out of the valley center.
  • Pipes. Use a flexible boot made for metal roofs. Place it so its base sits in the flat of the panel and does not block the channel between ribs, where it would dam water. Avoid setting a pipe through a seam.

Snow and Ice

Snow slides off metal all at once. A sliding load can tear off gutters, crush plants and hurt people below. Where the design calls for snow guards, install them in the pattern and fastening the guard maker specifies, especially over doors and walkways.

Working on Metal Safely

  • Metal panels are slippery when wet, frosty, dusty or freshly unpacked with factory oil on them. Many crews avoid walking on them at all in the early morning.
  • Walk in the flats over the supports, not on the ribs or seams, which dent.
  • Never carry long panels in wind. Use two or more people and turn the panel edge into the wind.
  • Keep fall protection connected. The OSHA residential rule applies at 6 feet.
  • Metal conducts. Look up for power lines before you lift or swing a panel or a length of trim.

Common Mistakes

Mistake What it costs
Cutting with an abrasive wheel Rusted edges and rust spots across the panel
Leaving filings on the roof Rust stains within weeks
Overdriven or crooked screws Split washers and leaks at hundreds of holes
Skipping closures Wind-driven rain, birds and insects under the panels
Starting square to the rake, not the eave Panels that fan and crooked seams
Lead or copper next to steel panels Corrosion where water runs off them
Screwing through a floating standing-seam panel Buckling, oil-canning and torn clips

Check Your Understanding

1. An owner wants exposed-fastener panels with no lap sealant on a 2:12 porch roof. Does the IRC allow it?

No. Lapped panels without lap sealant need at least 3:12. With the maker's lap sealant, they can go to 1/2:12, or a standing-seam system can go to 1/4:12.

2. An aluminum standing-seam panel is 24 feet long, and the temperature swing is 150°F. About how much does it move?

288 x 0.0000128 x 150 = 0.55 inch, a little over 1/2 inch.

3. A crew member trims panels with a cutoff wheel on a grinder, right next to the panel stack. What two problems follow?

The hot cut burns the coating at the edge, and hot filings land on the other panels and rust there. Use shears and cut away from the stack.

4. After eight panels, the gap from the last panel to the gable end is 1/2 inch bigger at the ridge than at the eave. What is happening?

The panels are fanning out of square. Correct it gradually as the maker allows, before it grows.

Key Takeaways

  • Lapped panels need 3:12 without sealant, and standing seam can go to 1/4:12, unless the maker requires more.
  • Metal moves. Clips, fixed points and screw patterns are designed around that.
  • Shear metal. Do not grind it, and sweep filings off the same day.
  • Drive screws straight and snug, with the washer just compressed.
  • Keep copper, lead and treated wood away from steel panels and their runoff.
  • Start square to the eave, install closures, and check often for fanning.