Skip to content

Removing Old Flooring Safely

15 min read Training Guide

Plan a floor tear-out, recognize flooring and adhesive that may contain asbestos, know when to stop and test, and remove carpet, wood, tile and underlayment without injury.

Table of contents

Tear-out is the dirtiest and most physical part of a flooring job, and it is where workers most often disturb asbestos without knowing it. Old vinyl tile, the backing on old sheet vinyl, and black adhesive can contain asbestos fibers. Intact, they are low risk. Sanded, ground, dry-scraped, broken or torn, they release fibers that can cause lung disease and cancer decades later. You cannot tell by looking. The decision to test comes before the first scraper touches the floor.

What You Will Be Able to Do

  • Check a floor and its building before tear-out.
  • Recognize flooring and adhesive that must be treated as asbestos.
  • Explain what testing involves and when to stop work.
  • Remove carpet, floating floors, wood, tile and underlayment with the right method.
  • Control dust, debris and the injuries tear-out causes.

Before You Pull Anything

  1. Find out what is there. Look at the edges at floor registers, thresholds and closets. Floors often hide two or three layers. Do not cut a sample yourself.
  2. Ask for records. Many commercial and apartment buildings have an asbestos survey. Ask the owner or your supervisor for it before work starts.
  3. Know the building's age. Older buildings call for more caution with flooring, adhesive and painted trim.
  4. Check what is under the floor. Radiant heat tubing or cables, wiring, pipes and ducts can sit right below the surface. Know how deep any saw cut can go.
  5. Plan the debris route. Set the dumpster or trailer, protect finished floors along the path, and keep the work area closed off from occupied rooms.
  6. Gear up. Wear cut-resistant gloves, safety glasses, knee pads, sturdy boots and hearing protection for power tools. Respiratory protection depends on the task and your employer's plan.

If the building was built before 1978 and you will remove painted baseboard or trim, lead-safe work rules may apply. Treat the paint as lead until it is tested.

Asbestos in Old Floors

Where It Hides

  • Vinyl asbestos and asphalt tile. 9-inch square tiles are a well-known sign of age, but 12-inch tiles can contain asbestos too.
  • Sheet vinyl backing. The felt or paper on the back of old sheet flooring can contain asbestos, and it tears apart easily during removal.
  • Black mastic. Black, tar-like "cutback" adhesive under old tile often contains asbestos.
  • Layers. A newer floor can sit on top of an older one, so a floor that looks modern can hide old tile underneath.

What the Rules Say

  • OSHA's construction asbestos rule (29 CFR 1926.1101) says asphalt and vinyl flooring installed in 1980 or earlier must be treated as asbestos-containing unless it is shown not to be. For removal work, it says resilient flooring, with its mastic and backing, is assumed to contain asbestos unless an industrial hygienist determines it does not.
  • Removing asbestos flooring is Class II asbestos work under that rule. Workers need training first, at least 8 hours with hands-on practice for a single material such as flooring, and the work must follow the rule's practices.
  • Those practices include: no sanding of flooring or backing; wet methods when cutting sheet flooring and scraping residue; no ripping up sheet flooring; no dry sweeping; HEPA vacuums with a metal floor tool and no brush; removing tiles whole where possible; and no mechanical chipping unless it is inside a negative-pressure enclosure.
  • EPA's asbestos rule (the asbestos NESHAP) requires an inspection before renovation or demolition in most commercial and public buildings and in apartment buildings with more than four units. Houses and small residential buildings are generally outside that federal rule.
  • States and cities add their own rules. Many require licensed abatement contractors, notice before work, and special disposal. Some cover houses too. The local rule wins.

Testing

A test tells you what the flooring and adhesive contain, so the right people can remove it the right way.

  1. Who samples. An accredited or state-licensed asbestos inspector takes the samples. On the job, you take a sample only if you are trained for it and your employer allows it.
  2. What gets sampled. Each layer separately: each tile type, the sheet flooring backing, each adhesive and any leveling compound.
  3. Who analyzes. An accredited laboratory. Material with more than 1 percent asbestos is treated as asbestos-containing.
  4. The method matters. The common microscope method, polarized light microscopy (PLM), can miss asbestos bound up in floor tile and mastic. EPA recommends transmission electron microscopy (TEM) to confirm floor tile results, and some states require it before a negative result counts.
Result What happens next
Not tested Treat it as asbestos. Stop and get it tested
Positive Trained crews remove it under the rules, licensed where the state requires, or the owner covers it in place where allowed
Negative, confirmed by the right method Normal tear-out with dust control

Covering in place. Leaving intact, well-bonded tile alone and covering it with new underlayment or a floating floor is often the lowest-risk choice. Fastening through it and the rules about it vary, so the owner should check with the asbestos professional and the state.

Warning: Never sand, grind, dry-scrape, bead-blast or break up suspect resilient flooring or black mastic. Do not tear up suspect sheet vinyl. Do not use a floor sander, grinder or power scraper on it.

When to Stop

Stop work and tell your supervisor if any of these is true:

  • The flooring or adhesive has not been tested and the building's records do not clear it.
  • You find black, tar-like adhesive.
  • You find a layer you did not expect.
  • Tiles are breaking into pieces or sheet backing is tearing.
  • Someone has already sanded, ground or scraped suspect material.

If material may already be disturbed:

  1. Stop. Do not sweep, blow or vacuum with a shop vacuum, which spreads fibers.
  2. Keep people out of the area and close it off.
  3. Ask your supervisor to have the forced-air heating or cooling serving the room shut off, so dust is not spread.
  4. Report it. The owner brings in an asbestos professional to assess and clean up.

Tear-Out Methods

These methods are for flooring that testing has cleared, or that is a newer material with no suspect layers.

Floor Method Watch for
Carpet and pad Cut into strips about 2 feet wide, roll, and carry out. Pull pad staples Tack strip nails, heavy rolls
Tack strip Pry up with a flat bar from under the strip Nails pointing up, flying pieces
Floating vinyl or laminate Remove trim and transitions, then unclick from the last row Foam or film underlayment to bag
Nail-down hardwood Cut a few boards lengthwise with a circular saw set to the floor's thickness, then pry from the cut Nails, splinters, what is under the floor
Glue-down plank Scrape or use a power scraper, check what residue the new floor allows Adhesive residue, blade injuries
Ceramic tile on thin-set or backer Chisel or rotary hammer in chisel mode, working under the tile Flying shards, silica dust, heavy debris
Tile on a thick mortar bed Break and remove in sections Very heavy debris, silica dust
Plywood or particleboard underlayment Cut into sections with a saw set to its depth, pry up, pull staples Fasteners, saw depth

Warning: Do not cut or remove underlayment that still has untested resilient flooring glued to it. Sawing through it disturbs the flooring just as sanding would.

Controlling Dust

  • Breaking tile and mortar makes silica dust. Use a tool with water at the point of impact or a shroud and dust collector, as OSHA's silica rule requires for powered chipping tools, and follow your site's silica plan.
  • Clean up with a HEPA vacuum or wet methods. Do not dry sweep.
  • Close off the work area with plastic sheeting where dust could reach occupied space.

Protecting Your Body

  • Hands. Retract utility knife blades when you set them down, change dull blades often, and wear cut-resistant gloves.
  • Feet. Pull or bend over nails and tack strip as you go. A tack strip nail goes through soft shoes.
  • Eyes. Tile shards and nails fly. Wear safety glasses at minimum.
  • Back. Debris adds up fast. Carry partial buckets, use a cart, and keep loads close to your body.
  • Knees. Tear-out is hours of kneeling. Wear knee pads.
  • Ears. Rotary hammers and saws are loud. Wear hearing protection.

After the Old Floor Is Out

  1. Remove or set every nail and staple.
  2. Look for rot, water damage, soft spots and broken panels, and report them.
  3. Check that any remaining adhesive residue is something the new flooring maker allows.
  4. Vacuum, then move on to checking flatness and moisture.

Common Mistakes

Mistake What it costs
Scraping black mastic dry to save time Asbestos exposure for you and the occupants
Assuming a floor is safe because it looks new An old layer disturbed underneath
Shop-vacuuming suspect debris Fibers spread through the building
Saw blade set too deep Cut heating tubes, wires or pipes
Leaving tack strip nails up Puncture wounds
Dry-chipping tile indoors Silica exposure and a silica violation

Check Your Understanding

1. A 1970s office has 9-inch tiles over black adhesive. The owner wants them ground off by tomorrow. What do you do?

Stop. Under OSHA's rule the flooring is presumed to contain asbestos. It must be tested, and if positive, removed by trained crews under the asbestos rules.

2. You pull up carpet and find sheet vinyl you did not expect. What now?

Stop and report it. Do not tear or scrape it until it and its adhesive have been tested.

3. A lab report says a floor tile is negative by PLM. Is that the end of the question?

Not always. PLM can miss asbestos in floor tile. EPA recommends TEM to confirm, and some states require it.

4. Testing clears a ceramic tile floor. You will break it out with a rotary hammer indoors. What dust control do you need?

Water at the point of impact or a shroud with a dust collector, plus HEPA or wet cleanup and the respirator your employer's silica plan requires.

Key Takeaways

  • Treat old resilient flooring, sheet backing and black mastic as asbestos until a test says otherwise.
  • Never sand, grind, dry-scrape or tear up suspect flooring.
  • Testing needs a trained inspector and an accredited lab, and floor tile may need TEM.
  • Federal, state and local rules all apply, and the strictest wins.
  • Stop, isolate and report if suspect material is disturbed.
  • Match the tear-out method to the floor, and control silica dust from tile.