The appliance over a range does two jobs. It pulls smoke, steam and grease away from the cooktop, and in the case of an over-the-range microwave, it cooks. When one fails, the usual fix is a replacement rather than a repair. A range hood has little inside worth fixing, and a microwave holds high-voltage parts that a maintenance or install worker never opens. Replacing either one well means a solid mount, the right venting, safe power and a unit that is level and quiet.

What You Will Be Able to Do

  • Explain why a microwave's outer cabinet stays closed
  • Check clearance, power and venting before you buy or hang a unit
  • Remove and install an over-the-range microwave on its wall plate
  • Remove and install a hardwired range hood with the power locked out
  • Do the small fixes that do not need the unit opened

Why a Microwave Stays Closed

A microwave oven makes its heat with a high-voltage transformer, a capacitor and a magnetron. Together they produce voltages many times higher than a wall outlet, and the capacitor can hold a lethal charge after the oven is unplugged.

Warning: Do not remove a microwave's outer cabinet or wrap, for any reason. The high-voltage capacitor inside can stay charged after the oven is unplugged and kill you if you touch it. Repairs inside the cabinet are for technicians trained by the maker. Replace the whole unit, or call one of those technicians.

Replacing an over-the-range microwave is safe because the unit stays sealed the whole time. You mount it, plug it in and test it, and you never open it.

Before You Buy or Hang

Size and Clearance

Measure the opening, the old unit and the cabinet above it. Many over-the-range microwave install guides call for at least 30 inches from the cooking surface to the bottom of the cabinet above, and set a minimum height from the floor as well. The range maker may set its own clearance for the cooktop. Check both install guides for the models you have. If the opening is too short, the unit does not belong there.

Power

Unit Usual power What to check
Over-the-range microwave Plugs into a 120-volt receptacle inside the cabinet above Most makers call for a grounded receptacle on its own circuit
Range hood Hardwired to a junction box, or a cord kit to a receptacle The circuit, the box, and that the wiring is in good shape

Adding a receptacle or a circuit is electrician work. So is any wiring that is damaged, scorched, missing a box, or aluminum.

Venting

Setup How it works Notes
Ducted to the outside The fan pushes air through a duct and out a wall or roof cap Removes heat, moisture and smoke
Recirculating (ductless) Air passes through a grease filter and a charcoal filter, then back into the kitchen Must be listed for ductless use. Charcoal filters need replacing
Over-the-range microwave Can usually be set either way by turning its blower Set it before you hang it

Under the International Residential Code, a ducted range hood must discharge outdoors through a smooth, airtight metal duct with a backdraft damper. It may not end in an attic, a crawl space or anywhere else inside the building. A listed ductless hood is allowed where the maker's instructions are followed. The code also requires makeup air, a planned way for outside air to come back in, for hood systems that can exhaust more than 400 cubic feet per minute. A bigger hood than the one you are replacing can trigger that rule, so check the rating before you upsize.

Like-for-like replacement keeps the existing duct. A new hole through a wall or roof, a new duct route, or a makeup air system is construction work, often with a permit.

Removing an Over-the-Range Microwave

You need two people. Most units weigh enough that one person cannot hold one overhead and work the bolts at the same time.

  1. Unplug the microwave. The plug is usually inside the cabinet above. If you cannot reach it, turn off the breaker.
  2. Empty the cabinet above. Cover the cooktop with a moving blanket or cardboard to protect it.
  3. Have your helper support the microwave from below with both hands.
  4. Inside the cabinet above, remove the bolts that come down through the cabinet floor into the top of the microwave. There are usually two or three.
  5. Tilt the front of the microwave down. Lift it so the slots at its back come off the hooks of the wall plate.
  6. Feed the cord down through the cabinet hole as you lower the unit.
  7. Set it down on a padded surface, upright.
  8. Remove the old wall plate from the wall.

Keep the old unit closed and in one piece. Recycle it through a program or hauler that takes appliances, as your local rules require.

Installing an Over-the-Range Microwave

Follow the new unit's install guide. It includes paper templates for the wall and the cabinet bottom.

  1. Find the studs. Mark them on the wall behind the opening.
  2. Hang the wall plate. Tape the wall template in place, level it, and mark the holes. The plate must be fastened into at least one stud, with the type and number of fasteners the install guide calls for. Use the supplied toggle bolts only where the guide allows them.
  3. Mark the cabinet holes. Tape the top template to the cabinet's underside and drill the bolt holes and the cord hole. Smooth the cord hole's edge, or add a grommet, so it cannot cut the cord. If the cabinet floor is recessed, use the filler blocks or spacers the guide describes.
  4. Set the exhaust. For outside venting, turn the blower and fit the damper as the guide shows, so it lines up with the existing duct. For recirculating, set the blower for that and plan to install the charcoal filter.
  5. Lift and hook it. With your helper, lift the unit, feed the cord up through the hole, and hook the slots at its back onto the wall plate's tabs.
  6. Swing it up and bolt it. Raise the front against the cabinet and start the top bolts by hand. Tighten them until the unit is snug and level, without crushing the cabinet floor.
  7. Connect the duct, if venting outside, so the damper opens freely. Seal the joint with foil tape listed for ducts.
  8. Finish and test. Plug it in. Install the grease filters and, if it recirculates, the charcoal filter. Run the fan on each speed, turn on the cooktop light, and heat a cup of water for a minute to confirm it cooks.

Replacing a Hardwired Range Hood

  1. Turn off the breaker, lock and tag it under your site's procedure, and prove the hood's wires dead with your meter.
  2. Remove the grease filters. Open the hood's wiring cover and photograph the connections.
  3. Disconnect the wires and loosen the cable clamp.
  4. Support the hood. Remove the screws holding it to the cabinet bottom or wall, and disconnect the duct. Lower it.
  5. Prepare the new hood. Remove the knockouts that match the existing duct and cable, and fit the damper on its outlet.
  6. Lift it into place, feeding the cable through a clamp, and fasten it as the install guide shows. Line up the duct.
  7. Connect the wires like for like: black to black, white to white, and the bare or green ground to the hood's ground screw or wire. Close the wiring cover.
  8. Seal the duct joint with listed foil tape. Check that the damper swings freely.
  9. Restore power and test every fan speed and the light. Go outside and check that air comes out of the wall or roof cap.

If the duct is smaller than the new hood's outlet, or the hood is much stronger than the old one, stop and check the install guide's duct size and the makeup air rule before you finish.

Small Fixes That Do Not Open the Unit

  • Grease filters. Metal mesh filters come out and can be cleaned in hot, soapy water or a dishwasher, as the maker allows. Clogged filters make the fan loud and weak.
  • Charcoal filters. These cannot be washed. Replace them on the maker's schedule.
  • Cooktop lights. Most hoods and microwaves have bulbs under the unit, behind a small cover you reach from below. Use the bulb type the maker lists. Replace only bulbs the use-and-care manual shows as owner-replaceable.
  • Door, turntable and controls on a microwave. If anything else fails, replace the microwave or call a maker-trained technician.

Common Mistakes

Mistake What it costs
Opening a microwave's cabinet A possibly fatal shock from the capacitor
Hanging the wall plate on drywall alone A microwave that pulls off the wall onto the cooktop
Forgetting to turn the blower before hanging Taking the unit down again
Leaving a rough cord hole A cut cord and a short
Venting a hood into the attic Grease and moisture in the building, against code
Upsizing a hood without checking makeup air A code violation, and a hood that pulls exhaust back down chimneys and flues

Check Your Understanding

1. An over-the-range microwave's light works, but it will not heat. A coworker suggests taking the cover off to check the fuse. What do you say?

No. A microwave's cabinet holds a high-voltage capacitor that can stay charged after unplugging. Replace the unit, or call a technician trained by the maker.

2. You find no stud where the wall plate's template lines up. What do you do?

Shift the plate within the template's range to catch at least one stud, as the install guide requires. Do not hang it on toggle bolts alone.

3. A resident wants a new hood rated at 600 cubic feet per minute to replace one rated at 250. What must be checked before installing it?

Makeup air. The code requires makeup air for hood systems that can exhaust more than 400 cubic feet per minute. Also check that the existing duct is the size the new hood needs.

4. The old microwave vented outside, and the new one arrives set for recirculating. When do you change it?

Before you hang it. Turn the blower and fit the damper as the install guide shows, so it lines up with the duct.

Key Takeaways

  • Never open a microwave's cabinet. Its capacitor can hold a lethal charge after unplugging.
  • Check clearance, power and venting against both install guides before you buy or hang a unit.
  • Fasten the wall plate into at least one stud, and lift with two people.
  • Lock out a hardwired hood's breaker and prove it dead before you touch the wires.
  • Range hood ducts end outdoors with a damper, and hoods over 400 cubic feet per minute need makeup air.
  • New ducts, new wall holes and new circuits are not like-for-like work.