Mechanical Drives & Power Transmission

Troubleshooting Pneumatic Circuits

15 min read Training Guide

Find why an air-powered machine is slow, weak, leaking or stuck by checking supply pressure under load, leaks, water, valves, speed controls and cylinders in a set order.

Table of contents

Compressed air runs clamps, grippers, presses, diverters and valves in plants of every kind. Air circuits are simpler than hydraulic ones, but their faults hide well. A pressure drop only shows up while the machine cycles. A leak hisses under the noise of the floor. Water and dirt build up in a valve for months before it sticks. The fix is a steady method: prove the air supply first, then work along the circuit from the regulator to the cylinder.

A few terms. An FRL is the filter, regulator and lubricator unit that prepares air for a machine, in that order along the flow. A directional valve sends air to one end of a cylinder and lets the other end exhaust. A flow control sets cylinder speed by restricting air. A muffler quiets the exhaust ports.

What You Will Be Able to Do

  • Check supply pressure while the machine runs, and find what is starving it.
  • Find air leaks and judge what they cost.
  • Trace water, dirt and oil problems in the air back to their source.
  • Tell a valve fault from an electrical fault, and a valve leak from a cylinder leak.
  • Set speed controls and cushions, and fix slow, jerky or slamming cylinders.

Warning: Air stored in receivers, lines and cylinders can move a machine after it is shut off. Exhaust it and lock out before you open a line or reach into the machine. Never point an air nozzle at anyone or hold it against skin, because air can enter the body through a break in the skin. OSHA allows compressed air for cleaning only when reduced to less than 30 psi, with chip guarding and protective equipment.

Work Along the Air Path

Air travels from the compressor through a dryer and receiver tank, along the header pipe, down a drop to the machine, through the FRL, into the valves, through the flow controls to the cylinder, and out the exhaust. A fault can sit anywhere on that path.

What you see Where to look first
Every motion on the machine is slow or weak Supply: drop line, FRL, regulator setting
Several machines are weak at the same time Plant supply: compressor, dryer, header
One cylinder is slow, weak or jerky That cylinder's valve, flow controls, tubing, muffler
Air blows from an exhaust port at rest A valve seal or a cylinder piston seal
Water or oil spits from exhausts Drains, dryer, lubricator setting

Start by asking the operator what changed and when, just as with any fault. Then read the machine's pneumatic schematic, which shows each valve, what it drives, and where the regulators and flow controls sit.

Check Pressure While the Machine Runs

A gauge that reads correctly with nothing moving proves very little. The real test is the pressure during a cycle, when the cylinders are drawing air. If something upstream is too small or partly blocked, pressure sags each time air is used.

The US Department of Energy (DOE) says a properly designed air system should lose much less than 10 percent of the compressor's discharge pressure between the compressor and the point of use.

Worked example. A clamp cylinder has a 2-inch bore. The machine regulator is set at 80 psi.

  1. Piston area = 0.785 x 2 x 2 = 3.14 square inches.
  2. At 80 psi, clamp force = 3.14 x 80 = about 251 pounds.
  3. You watch the regulator gauge while the machine cycles. It falls to 62 psi each time three cylinders move at once.
  4. At 62 psi, force = 3.14 x 62 = about 195 pounds. The clamp loses about a fifth of its grip, which is why parts slip.
  5. The header gauge upstream holds 100 psi the whole time, so the restriction is between the header and the regulator.

Look for these, in order:

  1. A loaded filter element. Many filters have a differential pressure gauge or indicator. Change the element when it reaches the maker's limit.
  2. A drop line, hose or quick-connect coupling too small for the machine's air use.
  3. A kinked or crushed hose.
  4. A regulator too small for the flow, or one that has failed.

Raising the header pressure to cover a restriction is a common shortcut. It costs energy on every machine in the plant and leaves the fault in place. Fix the restriction instead.

Find and Fix Leaks

DOE says leaks can waste 20 to 30 percent of a compressor's output, and that a leak program can bring that under 5 to 10 percent. DOE's leak table puts a single hole 1/16 inch across at about 6.5 cubic feet of air a minute at 100 psig, running every hour the system is pressurized. Leaks also lower system pressure, so machines start to act weak.

DOE lists the common leak spots as couplings, hoses, tubes and fittings, pressure regulators, open condensate traps and shut-off valves, and pipe joints, disconnects and thread sealants.

How to find them:

  • Ultrasonic leak detector. DOE names this the best way. It picks up the high-pitched hiss of a leak even on a noisy floor, and it works while equipment runs.
  • Leak-detection fluid or soapy water. Brush it on a suspect joint and watch for bubbles. It is reliable but slow.
  • Never use your hand to feel for a leak.

Tag each leak with its location, fix it, and recheck. DOE recommends leak checks on a regular schedule rather than only when someone hears one.

Water, Dirt and Oil in the Air

Air coming out of a compressor is hot and full of water vapor. As it cools in the pipes, the water condenses. If drains and dryers do not remove it, it travels to the machine.

Sign Likely cause Fix
Water in the filter bowl or spitting from exhausts Drain stuck or not emptied, dryer down Drain the bowl, fix the automatic drain, report the dryer
Rust or sludge inside valves Water and dirt over time Clean or replace the valve, fix the source
Oily exhaust mist Lubricator set too high Turn it down to the maker's drip rate
Valve sticks after sitting overnight Varnish or dirt on the spool Clean or replace, check upstream filtering

Check that automatic drains actually open, not only that they are fitted. On lubrication, follow the valve maker: oiled air washes the factory grease out of parts built for dry air, so never add or remove a lubricator without checking first.

Valve Faults

When a cylinder will not move, find out whether the valve is getting its signal, and whether the valve can shift.

  1. Look for the signal. Many solenoid connectors have a light that turns on when the coil gets power. If the light is off when it should be on, the problem is electrical or in the controls.
  2. Try the manual override, if your procedure allows it. This is a button or screw on the valve that shifts it by hand. Clear the area first, because the cylinder will move.
  3. Read the result:
    • The override works but the solenoid does not: the fault is on the electrical side. Have a qualified electrical worker check the signal and the coil.
    • Neither works: the valve is stuck, or it lacks pilot air. Many valves use a small flow of supply air to shift the spool, and they need a minimum pressure, listed by the maker, to do it.

A coil that buzzes or keeps burning out is a clue. An AC solenoid draws a high current until its plunger pulls all the way in. If dirt or a sticky spool stops the plunger short, the coil stays at that high current and overheats. A new coil will burn out the same way, so find what is stopping the plunger.

Air blowing from an exhaust port at rest means a seal is passing. It can be the valve spool seals or the cylinder's piston seal. To tell which, find the valve outlet that feeds the cylinder's exhausting side. Exhaust and lock out the air, disconnect that outlet's tube, cap the valve outlet, and point the open tube away from people. Restore air. If the exhaust still blows, the valve is leaking. If it stops and air flows from the open tube instead, the cylinder's piston seal is passing.

Cylinder Speed and Cushions

On a double-acting cylinder, flow controls normally meter out, restricting the air leaving the cylinder. Each one has a built-in check valve, so it works in only one direction. If one is fitted backward or on the wrong port, it controls the wrong stroke, or the cylinder runs jerky because it is metering air in.

To set speed:

  1. Start with the flow control nearly closed.
  2. Cycle the cylinder and open the control in small steps until the speed is right.
  3. Lock the setting, and record it.

Cushions slow the piston for the last part of its stroke so it does not slam. On cylinders with adjustable cushions, a needle screw sets how much. Turn it in a little at a time until the piston settles in without bouncing or slamming. A cushion cannot make up for a cylinder running far too fast, so set speed first.

Symptom Table

Symptom Likely cause First check
Slow on one stroke Flow control, clogged muffler, kinked tube Turn the control, inspect the muffler
Slow on both strokes Low pressure, small supply, valve too small Gauge reading during the cycle
Jerky at low speed Pressure too low, dry seals, binding, meter-in Pressure, lubrication, mechanics
Slams at end of stroke Too fast, cushion open Slow it, then set the cushion
Will not hold position Piston seal, valve center type, leaks Exhaust port at rest, schematic
Leaks at the rod Worn rod seal, scored rod, side load Rod surface, alignment

A clogged muffler is easy to miss. Dust and oil plug it, and the cylinder slows on the stroke that exhausts through it. Replace it rather than removing it, since an open exhaust is loud and can throw debris.

A rod that leaks again soon after a seal change points to a scored rod or a side load from poor alignment. Check the rod and the mounting before you fit another seal.

Common Mistakes

  • Reading pressure only at rest. The drop shows up during the cycle.
  • Turning up the plant pressure. It costs energy everywhere and hides the restriction.
  • Swapping coils without finding why the last one burned.
  • Removing mufflers to speed up a cylinder.
  • Using thread tape on pneumatic fittings carelessly. Shreds of tape travel into valves and jam them. Use the sealant the fitting maker names.

Check Your Understanding

  1. A gripper drops parts only when several cylinders move at once. The regulator gauge reads 80 psi at rest. What do you check?
    Answer: Watch the gauge during the cycle. If it sags, look upstream for a loaded filter element, a small or kinked supply line, or an undersized regulator.

  2. A solenoid valve's light comes on, but the cylinder does not move. The manual override does not move it either. What does that tell you?
    Answer: The signal is getting there, and the valve still cannot shift. The valve is stuck or lacks pilot pressure, so the electrical side is not the first suspect.

  3. Air hisses constantly from a valve's exhaust while the machine sits idle. How do you find out whether the valve or the cylinder is leaking?
    Answer: Exhaust and lock out the air, disconnect the tube from the valve outlet that feeds the exhausting side, and cap that outlet. If the hiss continues with air restored, the valve leaks. If it stops and air comes from the open tube, the cylinder's piston seal is passing.

  4. A new cylinder retracts too slowly, and turning its flow control changes the extend speed instead. What is wrong?
    Answer: The flow control is controlling the wrong stroke, most likely because it is fitted backward or on the wrong port. Refit it so it meters the air leaving on the retract stroke.

Key Takeaways

  • Check pressure while the machine cycles, not only at rest.
  • Find leaks with an ultrasonic detector or leak fluid, never your hand, and recheck after the repair.
  • Water spitting from exhausts means drains or the dryer have failed upstream.
  • Use the light and the manual override to split electrical faults from valve faults.
  • A buzzing or repeatedly burned AC coil means the plunger is not seating.
  • Set speed with meter-out controls first, then set the cushions.