Skip to content
Skills / Door & Window Installation / Door and Window Installation / Hanging a Prehung Interior Door
Door & Window Installation

Hanging a Prehung Interior Door

15 min read Training Guide

Check the rough opening, set a prehung door plumb with the hinge side shimmed first, keep the reveals even, and test the swing and latch before the casing goes on.

Table of contents

A prehung door comes already hung on its hinges in its own frame, called the jamb. You do not cut hinge mortises or bore the lockset. Your job is to set that frame in the wall opening so it is plumb, square and flat, then fasten it without bending it. When that goes right, the door swings freely, stays where you leave it, and latches with a soft click. When it goes wrong, the door rubs, drifts open, or misses the strike, and casing will not hide it.

This guide covers interior swinging doors with a one-piece flat jamb. Exterior doors need sill pans, flashing and air sealing, which are a different job.

What You Will Be Able to Do

  • Read a door's size and check it fits the opening and the wall thickness.
  • Check a rough opening for plumb, level and twist, and fix the floor height.
  • Shim and fasten the hinge side first, then the latch side, keeping even reveals.
  • Diagnose a door that drifts, rubs or misses the latch.
  • Know when a door has rules that mean you should not swap it.

Before You Start

Read the Size

Doors are named by width and height in feet and inches. A 2868 door is 2 feet 8 inches wide and 6 feet 8 inches tall, which is 32 by 80 inches. A 3068 is 36 by 80.

Check four things against the order before you unwrap the unit:

Check Why
Width and height A wrong size will not fit the opening
Swing and hinge side The door must open the way the room needs
Jamb width It must match the wall thickness
Core Solid-core doors weigh more and often need screws as well as nails

Handing is the name for which side the hinges are on and which way the door swings. Suppliers do not all use the same rule to name a left-hand or right-hand door. Sketch the opening from above, show where the hinges go and which way the door swings, and confirm it with the supplier.

Jamb width must equal the wall thickness. A wall of 2x4 studs, which are 3-1/2 inches deep, with 1/2-inch drywall on both sides is 4-1/2 inches thick, so the standard jamb is 4-9/16 inches, a hair wider. A 2x6 wall takes a 6-9/16-inch jamb. Plaster or thicker drywall changes the number, so measure the wall.

Check the Rough Opening

The rough opening is the framed hole in the wall. Many makers size it about 2 inches wider than the door and about 2 to 2-1/2 inches taller, so there is room for the jamb plus shims. Some want less. Use the maker's chart.

  1. Measure the width at the top, middle and bottom. It should be about the same everywhere.
  2. Check both sides for plumb with a 4-foot or longer level. Note which way and how far each side leans.
  3. Check the floor across the opening with a level. Note how much higher one side is than the other.
  4. Check the wall thickness at both sides of the opening, top and bottom.
  5. Check for twist. Hold a straightedge across the opening at the floor and look along the wall. If one side of the opening sits in front of the other, the wall is twisted, and the jamb will follow it unless you correct for it.
Problem What to do
Opening too narrow for the unit Stop. Do not cut studs or headers, which may carry load. Get the right door or ask who handles framing
One side out of plumb a little Shims take it up. That side gets thicker shims at one end
Floor out of level Trim the jamb leg on the high side so the head jamb is level
Flooring not installed yet Set the jamb legs on blocks as thick as the finished floor will be
Wall thicker than the jamb Plan jamb extensions before you set the unit

Plan the Floor Gap

Leave room between the bottom of the door and the finished floor. Most prehung doors come with a gap built in. If the room returns air to the heating system under the door, it may need a bigger gap than usual, so check the HVAC plan. Never let the door rub on carpet or a rug.

Setting the Door

Warning: Prehung units are heavy and awkward, and solid-core doors can weigh more than a person can safely lift alone. Get help carrying and tipping the unit into the opening. Keep the door closed and held in the frame while you move it.

  1. Prep the unit. Leave any spacer shims that come in the gap between the door and the jamb until the jamb is fastened. Remove shipping clips or nails the way the instructions say.
  2. Trim for the floor. If the floor is out of level, cut the jamb leg on the high side by the difference, so the head jamb will be level.
  3. Set it in the opening. Center it, and push it in until the jamb edges are flush with the wall on both sides.
  4. Shim the hinge side first. Slide pairs of tapered shims, one from each side so they make a flat pack, between the jamb and the stud behind each hinge. Shim pairs keep the jamb flat. A single tapered shim tips it.
  5. Plumb the hinge jamb in both directions. Check the face of the jamb, along the wall, and the edge of the jamb, through the wall. Adjust the shims until it reads plumb both ways.
  6. Fasten the hinge side. Drive two finish nails, about 8d or 2-1/2 inches, through the jamb and the shims into the stud at each hinge. On solid-core doors, use the finish screws the maker calls for.
  7. Add a long hinge screw. Remove one short screw from the jamb leaf of the top hinge, and replace it with a 2-1/2 to 3-inch screw that reaches the stud. Doing the same on each hinge holds a heavy door. Snug it against the shims. Overdriving it bows the jamb back toward the stud and pulls the door with it, which opens the latch-side gap unevenly. Carpenters use that same pull on purpose, a little at a time, to lift a door off the head jamb when it rubs at the top latch corner.
  8. Close the door and set the latch side. Shim behind the strike area, then near the top and bottom of the latch jamb. Adjust until the gap between the door and the latch jamb is even from top to bottom and matches the gap at the top.
  9. Check the head. The gap across the top should be even. If it tapers, the head is not level. Adjust before you nail the latch side.
  10. Fasten the latch side with two nails at each shim pack.
  11. Trim the shims flush with the wall. Score them with a utility knife and snap them, or cut them with an oscillating tool, so the casing will sit flat.
  12. Install the lockset in the prebored holes, and adjust the strike plate if the latch does not catch cleanly.

The Gaps You Want

Gap Target
Hinge side Even, about 1/8 inch, as set at the factory
Latch side Even, about the same as the hinge side and top
Top Even across the width
Bottom What the maker and the HVAC design call for

On most units the factory sets these gaps for you. Your job is to keep them even by not twisting or bowing the jamb.

Testing the Door

Work through these checks before anyone puts up casing.

  1. The swing test. Open the door to several positions and let go. It should stay where you leave it. If it swings open or closed by itself, the hinge jamb is not plumb.
  2. The stop test. Close the door slowly. It should touch the stop along its whole height at once. If the top touches and the bottom does not, or the reverse, the jamb is twisted. Move the bottom of the latch jamb in or out until the door meets the stop evenly.
  3. The latch test. The latch should click into the strike without slamming or lifting the door.
  4. The gap test. Look at all the gaps again. They should be even.

The string test for twist. Before you fasten the latch side, stretch two strings across the face of the jamb, each from one top corner to the opposite bottom corner. Where they cross, they should just touch. If one string presses hard into the other or there is a gap between them, the jamb is twisted. Move one leg in or out until the strings just kiss.

Fixing Problems

Symptom Likely cause Fix
Door swings open or closed by itself Hinge jamb out of plumb Reset the hinge side shims
Rubs at the top on the latch side Head out of level, or door sags Recheck the floor trim, add a long screw at the top hinge
Latch side gap is narrow in the middle Too much shim at the strike Swap in a thinner shim pair at the strike
Latch side gap wide near one hinge Long hinge screw overdriven Back off the screw, add shim behind that hinge
Door hits the stop unevenly Jamb twisted Move the bottom of the latch jamb
Latch misses the strike Latch side too high, low or far Adjust shims, then the strike plate
Door rubs the floor Floor higher than planned, or rug Trim the door bottom, or raise the unit for the flooring

Doors to Leave Alone

Some doors are part of a building's fire protection. A door between a house and an attached garage has its own rules in the residential code, such as solid construction and a minimum thickness, and many areas require it to close by itself. A door in a hallway or stair of an apartment building may carry a fire label on its edge or hinge side. Do not replace either with a hollow-core interior door, and do not cut, plane or drill a labeled fire door. Ask the supervisor or the property's rules before you touch one.

Common Mistakes

Mistake What it costs
Not checking the floor first A slanted head jamb and a tapered top gap
Single shims instead of pairs A jamb tipped out of flat
Shimming the latch side first A hinge side you cannot plumb
Overdriving the long hinge screw A bowed jamb and uneven gaps
Casing before testing the door Pulling off new casing to fix the door
Wrong handing A door that opens into the wrong side of the room

Check Your Understanding

1. You are about to hang a 3068 door in a 2x4 wall with 1/2-inch drywall on both sides. What size is the door, and what jamb width do you need?

It is 36 by 80 inches. The wall is 4-1/2 inches thick, so a standard 4-9/16-inch jamb fits.

2. The floor across the opening is 1/4 inch higher on the latch side. What do you do before you set the unit?

Cut 1/4 inch off the bottom of the latch-side jamb leg, so the head jamb sits level.

3. A newly hung door drifts closed every time someone opens it halfway. What is wrong, and where do you look?

The hinge jamb is not plumb. Recheck it in both directions and reset the hinge side shims.

4. The door touches the stop at the top but has a 1/8-inch gap at the bottom when closed. What do you adjust?

The jamb is twisted. Move the bottom of the latch jamb toward the door until it meets the stop evenly.

5. A homeowner wants a lighter hollow-core door between the house and the garage. What do you say?

No. That door has its own code rules for construction and closing. Replace it only with a door that meets them.

Key Takeaways

  • Check the size, swing, jamb width and rough opening before you unwrap the unit.
  • Trim for the floor so the head is level, and set the jamb flush with the wall.
  • Shim the hinge side first in pairs, plumb it both ways, and add a long screw at the top hinge.
  • Set the latch side for an even gap, and test swing, stop and latch before casing.
  • Leave garage and labeled fire doors to their own rules.