Installing an Exterior Prehung Door
Check the opening and sill, set an exterior prehung door on a sill pan, shim and fasten it for security, adjust the threshold to seal, and air seal the gap without bowing the jambs.
Table of contents
An exterior door does three jobs an interior door does not. It keeps water out at floor level, where water collects. It seals against wind and cold with weatherstrip that only works if the door is set exactly in plane. And it is the main thing standing between a house and a break-in. A door that swings fine but leaks at the sill, whistles at the corner or can be kicked open at the strike has not been installed right.
A prehung door comes with the slab already hung in its frame, with the sill, weatherstrip and usually the exterior casing, called brickmould, attached. This guide covers the exterior-specific work. Hanging and shimming follow the same logic as an interior prehung door, but every step here is checked against the weather and the lock. The door maker's installation instructions control and can void the warranty if skipped.
What You Will Be Able to Do
- Check a rough opening and subfloor for size, level, plumb and twist.
- Know the code basics for an exterior door: egress size, landing height and safety glass.
- Set a prehung unit on a sill pan with full sill support.
- Shim and fasten the hinge and latch sides, with long screws for security.
- Adjust the threshold and weatherstrip so the door seals, and air seal the frame.
Code Basics to Check First
Your adopted code and local amendments win. The International Residential Code includes these rules for houses:
| Item | Rule |
|---|---|
| Required egress door | At least one side-hinged door, with a clear width of 32 inches and a clear height of 78 inches |
| Opening from inside | The egress door must open from inside without a key, special knowledge or effort |
| Landing at the egress door | No more than 1-1/2 inches below the top of the threshold |
| Exterior landing exception | Up to 7-3/4 inches below the threshold, only if the door does not swing over it |
| Glass in the door | Safety glazing, such as tempered glass, unless the openings are too small for a 3-inch ball or the glass is decorative |
Three things to know:
- A 32-inch door does not give a 32-inch clear opening. The stop and the door's own thickness eat into it. A 36-inch door is the usual choice for the required egress door.
- An outswing door needs a landing close to threshold height, because the 7-3/4-inch step-down is allowed only when the door does not swing over the landing.
- The egress door must open from inside without a key, so a lock that needs a key on the inside does not meet that rule there.
Choosing the Unit
- Swing and hand. Inswing doors are most common. Outswing doors resist wind-driven rain and forced entry better, but their hinge pins face outside and need security pins or non-removable pins. "Hand" means which side the hinges are on, seen from outside.
- Jamb depth. It must match the wall: sheathing, studs and drywall. Too shallow leaves a gap to fill. Too deep sticks out past the drywall.
- Sill type. Adjustable sills have a cap that screws up and down to meet the door bottom. Check the sill height against the finished floor inside.
Removing the Old Door
- Pre-1978 buildings. Taking out a painted door and frame usually disturbs more painted surface than the federal lead rule's minor-repair limit, so it is covered renovation work. A certified firm and renovator must run it with lead-safe practices.
- Cut the paint and sealant lines with a knife before prying, so the siding and drywall do not tear.
- Pull the old casing, cut the nails or screws through the jambs with a reciprocating saw blade between the jamb and the framing, and remove the frame in one piece if you can.
- Look at the subfloor and framing under the old sill. Rot there is common and must be repaired before a new door goes in.
Check the Opening
- Size. Compare the rough opening with the maker's listed rough opening size, usually a little wider and taller than the unit so there is room to shim.
- Sill level. Lay a level across the subfloor in the opening. The sill must sit level and flat across its full length. Plane a high spot or build up a low one before the sill pan goes in.
- Jack studs plumb. Check both sides of the opening with a level.
- Twist. Hold a straightedge or level across the opening at the outside face of the wall, at the top and at the bottom. If the wall leans differently on one side, the latch jamb will not sit in the same plane as the hinge jamb, and the door will touch its weatherstrip at the top but not the bottom. Note it now.
- Floor height. Measure the finished floor height inside, including rugs or new flooring, so the door bottom will clear it.
Prepare the Sill
- Install a sill pan with a back dam and sealed corners, lapped over the weather barrier below, unless the door maker specifies another method. Never fasten through the flat of the pan.
- Apply sealant where the door maker's instructions show, under the sill and at the jamb ends. Use the sealant the maker approves for the sill and pan materials.
- Plan sill support. The sill must be supported along its whole length, including the interior edge. An unsupported sill flexes when people step on it, breaks its seal and cracks.
Set the Door
- Leave the shipping clips or screws that hold the slab closed in place until the frame is fastened on the hinge side, if the maker allows. They keep the frame square.
- Tip the unit into the opening from outside, setting the sill down into the sealant first, then the top in. Two people for this. Exterior units are heavy and top-heavy.
- Center it side to side, so the shim space is about equal on both sides.
- Tack the top of the hinge side through the brickmould or jamb, loosely, so it cannot fall.
Shim and Fasten the Hinge Side
- Shim behind each hinge. Use pairs of tapered shims, pointing opposite ways, so they stay flat.
- Plumb the hinge jamb in both directions: side to side and in and out. Use a 4-foot or longer level or a straight 6-foot level.
- Fasten through the jamb at each shim with the screws or nails the maker calls for.
- Replace a hinge screw with a long one. At each hinge, take out one of the short screws that go into the jamb, usually the one nearest the stop, and drive a long screw, often 2-1/2 to 3 inches, through the shims into the stud. Many doors come with these screws. This keeps the door from sagging and makes it far harder to pry or kick off.
- Do not over-drive. A screw pulled too tight bows the jamb toward the stud and changes the gap.
Shim and Fasten the Latch Side and Head
- Close the door and check the reveal, the gap between the slab and the jamb. It should be even along the latch side and the head, matching the gap the unit had from the factory.
- Shim the latch jamb at the top, at the bottom, and behind the lock strike and deadbolt strike. Adjust until the reveal is even.
- Check that the door meets the weatherstrip evenly from top to bottom. If it hits at the top and has a gap at the bottom, the latch jamb is twisted out of plane. Move the bottom of the latch jamb in or out until contact is even.
- Fasten through the shims.
- Shim and fasten the head only if the maker calls for it, and never so tight that the head jamb bows down.
Strike Security
The strike side is where a kicked door breaks. The short screws in most strike plates reach only into the thin jamb.
- Drive long screws, often 3 inches, through the strike plates into the framing, with a solid shim behind.
- If the door comes with a strike reinforcement plate, install it.
- Check that the deadbolt throws its full length without binding. A bolt that drags into its strike is not being used fully.
The Paper Test
Close the door on a strip of paper at several spots around the weatherstrip, including all four corners. Pull the paper. You should feel firm drag everywhere. If the paper slides out freely at one spot, the door is not sealing there. Adjust the jamb at that spot, not just the latch.
Adjust the Threshold
- Raise or lower an adjustable sill cap with the screws along its top until the door bottom sweep presses lightly on it. The paper test applies here too.
- Do not set it so high that the door drags or needs a shove to close.
- Check the door bottom for the drip edge or sweep the unit came with. A missing or torn sweep gets replaced before you leave.
Air Seal and Insulate
From inside, fill the gap between the jambs and the framing.
- Use low-expansion foam labeled for windows and doors, or backer rod and sealant. Standard expanding foam pushes jambs in and makes the door bind.
- Fill in layers, and do not overfill.
- After the foam cures, open and close the door again. If it binds, the foam bowed a jamb. Cut it back.
- Keep foam out of the space behind the strike and hinges where long screws go.
Finish the Outside
- Fasten the brickmould with corrosion-resistant fasteners into the framing.
- Flash the head and tie the jamb flashing into the weather barrier in shingle order, with a drip cap over the head trim where the instructions call for it.
- Seal the brickmould to the siding with an exterior sealant, but leave drain paths at the sill and weep holes open.
Final Checks
| Check | Pass |
|---|---|
| Door swings without rubbing and stays where you leave it | Yes |
| Reveal even on the latch side and head | Yes |
| Latch and deadbolt engage without lifting or pushing the door | Yes |
| Paper drags at every point of the weatherstrip and the sill | Yes |
| Long screws in hinges and strikes | Yes |
| Sill supported along its full length | Yes |
Common Mistakes
| Mistake | What it costs |
|---|---|
| Sill set on a subfloor that is not flat | A sill that rocks, cracks or leaks |
| No sill pan | Rot under the door within a few years |
| Shimming the latch side first | A hinge jamb out of plumb and a door that swings open on its own |
| Short screws at the strike | A door that kicks in |
| Ignoring twist in the opening | Weatherstrip that touches at the top and not the bottom |
| Standard expanding foam | Bowed jambs and a door that binds |
| Outswing door over a low landing | Fails the landing rule |
Check Your Understanding
1. The door seals at the top of the latch side, but paper slides out freely at the bottom. What is wrong, and how do you fix it?
The latch jamb is twisted out of plane with the hinge jamb. Move the bottom of the latch jamb toward the door, at the shims, until the weatherstrip contact is even.
2. An owner wants a 32-inch exterior door as the only egress door. What do you tell them?
A 32-inch door usually gives less than a 32-inch clear opening once the stop and door thickness are counted. The required egress door needs 32 inches clear, so a 36-inch door is the usual choice.
3. Why do you put a long screw in each hinge?
It ties the hinge into the framing, not just the thin jamb. That keeps the heavy door from sagging and makes it much harder to pry or kick off.
4. A house has a concrete stoop 6 inches below the threshold. Can an outswing door go there?
Not under the IRC rule. The 7-3/4-inch step-down is allowed only when the door does not swing over the landing. An outswing door needs the landing within 1-1/2 inches of the threshold, or use an inswing door.
5. After foaming the gap, the door starts to rub at the latch. What happened?
Too much foam, or the wrong foam, pushed the jamb in. Cut out the foam at that spot and refill with low-expansion foam.
Key Takeaways
- Check the opening for level, plumb and twist before the door goes in, and fix the sill first.
- Set the door on a sill pan with the sill supported along its full length.
- Shim and fasten the hinge side plumb first, then the latch side for an even reveal and even weatherstrip contact.
- Long screws at hinges and strikes hold the door and stop forced entry.
- Use low-expansion foam or backer rod and sealant, and check the swing again after it cures.