Skip to content
Mechanical Drives & Power Transmission

How Hydraulic Systems Work

20 min read Training Guide

Follow oil from the tank to the cylinder, name what each part does, and work out force, speed, pump flow and horsepower from the numbers on the machine.

Table of contents

Hydraulics moves heavy things with oil under pressure. Presses, balers, molding clamps, lift tables, dock levelers, forklift masts and loader arms all run on it. A small pump and a cylinder the size of your forearm can push with many tons of force, and hold that force with the motor off. To maintain these machines safely, you need to know what each part does, how pressure and flow behave, and where the energy sits when the machine is stopped.

What You Will Be Able to Do

  • Explain why flow sets a cylinder's speed and pressure sets its force.
  • Name the main parts of a hydraulic system and say what each one does.
  • Work out cylinder force, cylinder speed, pump flow and hydraulic horsepower.
  • Tell open-center, closed-center and pressure-compensated systems apart.
  • Know which normal readings to record so you can spot a change later.

Two Rules That Explain Most of Hydraulics

Pressure acts everywhere at once. Oil barely compresses. Push on oil in a closed space and the pressure rises the same amount everywhere in it. This is Pascal's law, and it lets a small pump push on a large piston and multiply force.

A pump makes flow, not pressure. The pump pushes a set volume of oil every turn. Pressure only builds when something resists that flow, such as a load on a cylinder, a closed valve or a narrow passage. A cylinder extending with no load may read 200 psi. When the same cylinder hits the part it is pressing, the pressure climbs until the cylinder moves the load or the relief valve opens.

That leads to the rule you will use most:

If you want to change Change this Not this
How fast it moves Flow (gallons per minute) Pressure
How hard it pushes Pressure (psi) Flow
The highest pressure allowed Relief or compensator setting Pump speed

Turning up the relief valve does not make a slow cylinder faster. It only raises the most force the system can make, and the heat it can make.

The Math You Will Use

All of these use inches, psi and US gallons. One gallon is 231 cubic inches.

Force

Force = pressure x piston area, and piston area = 0.785 x bore x bore.

On the rod side, the rod takes up part of the piston face, so the working area is the piston area minus the rod area.

Worked example: A cylinder has a 4-inch bore and a 2-inch rod, and the system runs at 1,500 psi.

  1. Piston area = 0.785 x 4 x 4 = 12.56 square inches.
  2. Rod area = 0.785 x 2 x 2 = 3.14 square inches.
  3. Rod-side area = 12.56 - 3.14 = 9.42 square inches.
  4. Extending force = 12.56 x 1,500 = 18,840 pounds.
  5. Retracting force = 9.42 x 1,500 = 14,130 pounds.

The same cylinder pulls with less force than it pushes, because the rod side has less area.

Speed

Speed in inches a minute = gallons a minute x 231 / area.

Worked example: The same cylinder gets 10 gallons a minute (GPM).

  1. Extending: 10 x 231 / 12.56 = 184 inches a minute, about 3 inches a second.
  2. Retracting: 10 x 231 / 9.42 = 245 inches a minute, about 4 inches a second.

It retracts faster, because the same flow fills a smaller space. While it retracts, the oil pushed out of the cap end is 10 x 12.56 / 9.42 = about 13.3 GPM, more than the pump makes. Return lines, valves and filters on that side must handle the larger flow.

Pump Flow

Pump flow in GPM = displacement in cubic inches a turn x rpm / 231.

Worked example: A pump moves 1.5 cubic inches a turn, and its motor runs at 1,760 rpm. Flow = 1.5 x 1,760 / 231 = about 11.4 GPM. If a cylinder runs slower than it used to, compare its speed with what this number says it should be.

Horsepower and Heat

Hydraulic horsepower = GPM x psi / 1,714.

Worked example: 10 GPM at 2,000 psi is 10 x 2,000 / 1,714 = about 11.7 horsepower. The electric motor is sized larger than that, because no pump is 100 percent efficient.

The same formula explains heat. Whenever oil drops from high pressure to low pressure without doing work, that power turns into heat. If all 10 GPM goes over a relief valve set at 2,000 psi, the system makes about 11.7 horsepower of heat. That is roughly the heat from an 8.7-kilowatt electric heater, poured into the oil.

The Parts of a Hydraulic System

Part What it does What to know
Reservoir Holds oil, lets air and dirt settle, sheds heat Breather, sight glass, baffles
Pump Turns motor power into flow Needs a clear suction line
Relief valve Caps the highest pressure Protects every part downstream
Directional valve Sends oil to one side of an actuator or the other Often moved by solenoids
Flow control Sets actuator speed Often has a bypass check
Check valve Lets oil pass one way only Can trap pressure in a cylinder
Cylinder Makes straight-line force Single or double acting
Hydraulic motor Makes rotation Drives conveyors, winches and wheels
Accumulator Stores oil under gas pressure Holds energy with the pump off
Filters Remove particles On suction, pressure or return lines
Cooler Removes heat Air or water cooled

Pumps

A fixed displacement pump moves the same volume every turn. Gear pumps are the common fixed type. They are simple and tolerate abuse. A variable displacement pump can change how much it moves each turn. Most of these are piston pumps.

A pressure-compensated pump is a variable pump that cuts its own flow as pressure reaches its setting. When every actuator has stopped, it makes only enough flow to make up for internal leakage, so it holds pressure without dumping oil over a relief. The system still has a relief valve as a backup, set above the compensator by the amount the machine's manual gives.

Piston pumps and motors leak a little oil inside on purpose to lubricate their parts. A case drain line carries that oil back to the tank. Never block or restrict a case drain. Pressure builds in the housing and can blow out the shaft seal or damage the pump.

A clogged strainer, a closed suction valve or oil too thick on a cold morning starves the pump. A starved pump makes a gravelly noise called cavitation, and it wears out fast.

Valves Do Three Jobs

  • Directional valves decide where oil goes: extend, retract or hold.
  • Pressure valves decide how much pressure is allowed. The relief valve caps the whole system. A reducing valve holds a lower pressure on one branch, such as a clamp that must not crush the part. A sequence valve lets oil into a second circuit only after pressure builds in the first.
  • Flow valves decide how fast. A flow control slows a cylinder by restricting oil going in or coming out.

Two valves deserve special attention because they hold loads. A counterbalance valve keeps a vertical load from running away when it is lowered, and it holds that load when the valve is centered. A pilot-operated check valve locks oil in a cylinder until pilot pressure opens it. Both mean a cylinder can hold full pressure with the pump off.

Actuators

A single-acting cylinder uses oil to push one way, and a spring or the load's weight brings it back. A double-acting cylinder uses oil both ways. Cushions are small restrictions near the ends of the stroke that keep the piston from slamming into the end cap.

A hydraulic motor works like a pump in reverse. Oil flow spins the shaft. Its speed comes from flow, and its torque comes from pressure.

Open Center, Closed Center and Load Sensing

The way a system handles oil while nothing is moving changes how it behaves and where heat comes from.

System Pump Valve centered Where you see it
Open center Fixed Pump flow goes straight to tank at low pressure Older tractors, loaders and log splitters
Closed center, fixed pump Fixed Pump flow goes over the relief, making heat Usually paired with an unloading valve or accumulator
Closed center, compensated Variable Pump holds pressure with almost no flow Many plant machines and power units
Load sensing Variable Pump holds a set margin above the highest load Many newer mobile machines

Worked example: A power unit has a fixed gear pump making 8 GPM, a closed-center valve and no unloading valve. Relief is set at 1,800 psi. The machine sits idle for two hours with the valve centered. All 8 GPM goes over the relief, which is 8 x 1,800 / 1,714 = about 8.4 horsepower of heat the whole time. That explains why the oil is too hot to touch at the end of a quiet shift.

The Fluid

Hydraulic fluid transmits power, lubricates moving parts, seals the tiny gaps inside pumps and valves, and carries heat away.

  • Mineral oil. Most plant systems run on petroleum anti-wear oil. It is sold by ISO viscosity grade, such as ISO VG 32, 46 or 68. The number is the oil's viscosity at 40°C, so a higher number is thicker oil.
  • Fire-resistant fluids. Where a leak could spray onto something hot, such as near furnaces, systems may run on water glycol, phosphate ester or another fire-resistant fluid.
  • Never mix fluids. Top off only with the fluid on the reservoir label. The wrong fluid can attack seals, change viscosity or cut fire resistance.
  • Heat ages oil. Machinery Lubrication notes that the rate oil oxidizes roughly doubles with each 18°F rise, and that the reaction is comparatively slow below 140°F. Hot oil also thins, which raises internal leakage and slows actuators. The fluid maker and machine maker give the normal range for your system.
  • Dirt and water. Particles too small to see wear pumps and make valves stick, so cap every open port during a repair. Milky oil points to water, and foam to air getting in.

Know What Normal Looks Like

When a machine is running well, record:

  1. Oil level, at the actuator position the reservoir label gives. Level drops as cylinders extend, because oil leaves the tank to fill them.
  2. Oil temperature after the machine has run an hour or more.
  3. Pressure at each gauge while working and while idle.
  4. Cycle times for each motion.
  5. How the pump sounds when the oil is warm.

A cycle two seconds slower, or oil 20 degrees hotter than last month, is an early warning.

Warning: A stopped pump does not mean zero pressure. Check valves, counterbalance valves and accumulators hold oil under pressure, and a gauge only reads the part of the circuit it is plumbed to. Lock out the machine and relieve and verify every stored source before you open any line.

Common Mistakes

Mistake What it costs Better habit
Turning up the relief to speed up a cylinder More heat and stress, no more speed Check flow, the pump and the flow controls
Topping off with whatever oil is nearby Seal damage, lost fire resistance Use the fluid on the reservoir label
Checking level with cylinders extended Overfilling when they retract Check at the position on the label
Blocking a case drain Blown shaft seal or damaged pump Keep the drain open to the tank
Leaving ports open during a repair Dirt in valves and pumps Cap every open port and hose end
Ignoring hot oil Short oil and seal life Find where the heat comes from

Check Your Understanding

1. A press cylinder has a 5-inch bore and the system runs at 1,800 psi. How much force can it push with?

Area = 0.785 x 5 x 5 = 19.6 square inches. Force = 19.6 x 1,800 = about 35,300 pounds, close to 18 tons.

2. A pump makes 8 GPM. The cylinder has a 3-inch bore and a 1.5-inch rod. How fast does it extend, and how fast does it retract?

Piston area = 7.07 square inches, so extending is 8 x 231 / 7.07 = about 261 inches a minute. Rod area = 1.77, so the rod side is 5.30 square inches, and retracting is 8 x 231 / 5.30 = about 349 inches a minute.

3. A cylinder has grown slow over a month. A coworker suggests raising the relief valve setting. Will that fix it?

No. Speed comes from flow. A slow cylinder points to less flow reaching it, such as a worn pump or oil leaking past seals inside a valve or cylinder. Raising the relief only adds heat and stress.

Key Takeaways

  • Flow sets speed, pressure sets force, and the relief or compensator caps the pressure.
  • Force = pressure x area, speed = GPM x 231 / area, and horsepower = GPM x psi / 1,714.
  • Pressure dropped without doing work becomes heat, so oil going over a relief heats the system.
  • Counterbalance valves, pilot-operated checks and accumulators hold pressure with the pump off.
  • Use only the fluid the machine calls for, keep it cool and clean, and cap open ports.
  • Record normal level, temperature, pressure and cycle times so you can see a change.