Pump Packing and Mechanical Seals
Repack a pump stuffing box and set its leak rate, check a shaft before a mechanical seal goes in, install a cartridge seal, run its support system and read a failed seal for the cause.
Table of contents
Where a pump shaft leaves the casing, something has to keep the liquid in. Pumps use one of two methods. Compression packing is rings of braided material squeezed around the shaft, and it is meant to leak a little to stay cool. A mechanical seal is two very flat faces, one turning and one still, that run on a thin film of liquid and should show no steady drip. Both fail early when they are installed carelessly, and a seal leaking a hot or toxic liquid can burn or poison someone.
What You Will Be Able to Do
- Tell packing from a mechanical seal and know which services call for each.
- Size, cut, install and run in a set of packing to the right leak rate.
- Check shaft runout, end play and finish against a seal maker's limits.
- Install a cartridge seal and get it running without a dry start.
- Read a failed seal's faces and O-rings for the cause.
Packing or Seal
| Compression packing | Mechanical seal | |
|---|---|---|
| Leakage | Needs a steady drip | No visible steady leak |
| Upkeep | Gland adjustment, repacking | Little until it fails |
| Wear part | Packing and sleeve | Seal faces |
| Typical use | Water, slurry with flush, older pumps | Chemicals, hot or toxic liquids, clean services |
Hazardous, toxic or flammable liquids generally call for mechanical seals, often dual seals, because packing leaks by design. Your site's process safety rules decide that, not the technician.
Safety First
Lock out and isolate the pump, drain it and confirm zero pressure before you remove a gland, pull packing or touch a seal. Read the safety data sheet for the liquid.
Pump makers describe packing gland adjustment as a job done on a running pump. The Goulds 3196 manual says the packing can be checked without shutting down, and the leak rate is set with the gland nuts. Do it only where your site's procedure allows, with the coupling guard in place and your hands never near the turning shaft. Wear no gloves or loose sleeves there. If you cannot reach the nuts that way, lock out between adjustments. Never repack, pick at or touch packing on a running pump.
How Packing Works
The stuffing box is the bore around the shaft where the packing rings sit. The gland (or gland follower) presses on the rings and is tightened with two nuts. A lantern ring is a spacer with holes that lines up with a port in the box, so clean flush water can reach the middle of the packing.
The leak is the packing's coolant and lubricant. Squeeze it dry and the rings burn, harden and cut a groove into the sleeve. The Goulds 3196 manual gives these guidelines:
- With a clean liquid and box pressure above atmospheric, a gland leak of 40 to 60 drops per minute is usually enough to lubricate and cool the packing.
- During normal running, packing should leak about one drop per second.
- When the liquid is dirty or abrasive, or the box runs below atmospheric pressure (suction lift or vacuum), connect an outside source of clean flush to the lantern ring, about 15 psi above the stuffing box pressure.
Repacking a Pump, Step by Step
These steps follow Chesterton's packing installation instructions, with the gland adjustment from the Goulds 3196 manual.
- Lock out, isolate and drain the pump.
- Remove the gland and pull every old ring with a packing puller. Do not scratch the sleeve. Count the rings and note where the lantern ring sat.
- Clean the box completely of old packing, solids and corrosion.
- Inspect the sleeve. Replace it if it is scored, grooved, pitted or worn. New packing on a grooved sleeve leaks from day one.
- Measure the sleeve diameter, the box bore and the box depth with a caliper.
- Work out the ring size and count. Cross-section = (bore - sleeve diameter) ÷ 2. Number of rings = box depth ÷ cross-section.
- Cut rings on a mandrel the same diameter as the sleeve. Wrap the packing, mark one ring and cut it with a butt (square) or skive (angled) cut, as the packing maker says. Check each ring's fit before you cut the next.
- Install one ring at a time. Tamp each ring fully to the bottom before the next one goes in. Stagger the joints 90 degrees apart.
- Place the lantern ring so it lines up with the flush port. On the Goulds 3196, for example, the order is two rings, the lantern ring, then three rings.
- Install the gland and run the nuts down finger tight. Chesterton says the gland nose should just enter the box, about 1/8 to 3/16 inch.
- Start the pump and let it leak freely. Then tighten each gland nut evenly, about a quarter turn at a time, waiting between moves so the packing can settle and the leak rate can steady.
- Never stop the leak. If it stops completely, back the gland off and set it again.
- Replace the packing if tightening will not bring the leak down to the target rate.
Worked Example: Sizing Packing
You measure a sleeve at 1.875 inches, a stuffing box bore of 2.625 inches and a box depth of 1.875 inches.
- Cross-section: (2.625 - 1.875) ÷ 2 = 0.750 ÷ 2 = 0.375 inch, which is 3/8-inch packing.
- Rings: 1.875 ÷ 0.375 = 5 rings.
- If the box has a lantern ring, its width takes up some of that depth. Follow the pump's drawing for how many rings go below and above it.
Use 3/8-inch packing, not whatever size is on the shelf. Oversize rings will not seat, and undersize rings leak.
Packing Trouble
| Symptom | Likely cause | Fix |
|---|---|---|
| Gland hot or smoking, little leak | Gland too tight, flush off | Back off the gland, restore flush |
| Leak will not come down | Packing worn out, grooved sleeve | Repack, replace the sleeve |
| Grooved sleeve | Overtightening, abrasives without flush | Replace sleeve, add or fix the flush |
How a Mechanical Seal Works
A seal has two primary faces. The rotating face turns with the shaft, and the stationary face sits in the gland. Springs or a bellows hold them together. A film of liquid a fraction of a thousandth of an inch thick runs between them. Secondary seals, usually O-rings, seal each face to its part.
Seal faces are lapped so flat that their flatness is checked with an optical flat and measured in helium light bands, each about 11.6 millionths of an inch. A fingerprint, a speck of grit or a dropped face can ruin them. Handle faces by their edges and keep them in their packaging until the moment they go in.
Warning: Never run a mechanical seal dry. The Goulds 3196 manual warns that even a few seconds of dry running can cause seal failure and injury. Fill and vent the pump and the seal chamber before every start.
| Type | What it means |
|---|---|
| Component seal | Loose parts set on the shaft by measurement. Easy to set wrong |
| Cartridge seal | Preassembled on its own sleeve and preset by the maker |
| Dual, unpressurized | Two pairs with a buffer fluid at lower pressure than the process |
| Dual, pressurized | Two pairs with a barrier fluid at higher pressure, so the inner seal leaks barrier fluid in, not process fluid out |
| Pusher seal | An O-ring slides along the shaft as the faces wear |
| Bellows seal | A metal or rubber bellows flexes, with no sliding O-ring |
Seal Support Plans
API 682 numbers the common support piping plans that keep seal faces cool, clean and wet. You will see the numbers on seal drawings and tags:
| Plan | What it does |
|---|---|
| 11 | Pipes liquid from the pump discharge into the seal chamber |
| 23 | Circulates seal chamber liquid through a cooler |
| 32 | Brings in clean flush from an outside source |
| 52 | Reservoir of unpressurized buffer fluid for a dual seal |
| 53A | Gas-pressurized reservoir of barrier fluid for a dual seal |
| 62 | Quench of steam or water on the outside of the seal |
On rounds, check that flush lines are open and flowing, coolers are working, and reservoir levels and pressures match the last reading. A change in a dual seal reservoir's level or pressure is an early sign that one of the seals is leaking. Report it.
Before a Seal Goes In: Check the Pump
A new seal on a bent shaft or worn bearings fails just like the old one. Chesterton's instructions for one of its cartridge seals (the 155) list these checks:
| Check | Limit |
|---|---|
| Shaft or sleeve diameter | Within 0.002 inch of nominal |
| Shaft finish | No rougher than 32 microinches |
| Shaft runout at the seal | No more than 0.001 inch TIR per inch of shaft diameter |
| Shaft end play | No more than 0.005 inch TIR |
Other seals and pumps list their own limits, and the seal's instructions win. Remove burrs and sharp edges, and cover threads and keyways with thin tape so the O-rings do not get cut sliding over them.
Worked Example: Runout
You are fitting a seal on a 1.75-inch shaft. You set a dial indicator on the shaft where the seal will sit and turn the shaft one full turn by hand. The needle swings from -0.0012 to +0.0018 inch.
- Total indicator reading (TIR): 0.0018 - (-0.0012) = 0.0030 inch.
- Limit: 0.001 x 1.75 = 0.00175 inch.
- 0.0030 is more than 0.00175, so the seal must not go in yet. Check for a bent shaft, a worn sleeve or loose bearings first.
Installing a Cartridge Seal
- Check the pump against the seal's limits.
- Confirm the O-ring material suits the liquid, using the seal's chemical list.
- Lubricate O-rings with the lubricant supplied or named in the instructions. Never use petroleum oil or grease on EPDM O-rings, because it damages them. Keep lubricant off the faces.
- Slide the seal on without forcing it, and bolt the gland evenly so the faces are not distorted.
- Tighten the sleeve set screws to the torque in the instructions.
- Remove the setting clips or centering strap before start-up, and save them.
- Turn the shaft by hand. It should turn freely. Chesterton says metal-to-metal contact inside the seal means it is not centered.
- Connect the support plan, fill and vent the seal chamber, and start the pump only with liquid at the faces.
A component seal is instead set by measuring and marking its setting length from the seal drawing, so one wrong measurement crushes the springs or leaves the faces apart.
Reading a Failed Seal
Before you throw a failed seal away, look at it. Chesterton's seal troubleshooting series ties these face patterns to their causes:
| What you see | Likely causes |
|---|---|
| Radial cracks in the hard face (heat checking) | Dry running, too much heat, seal past its limits |
| Chipped face edges | Faces opening, liquid flashing to vapor, vibration, cavitation |
| Wear track wider than the narrow face | Seal not centered, shaft runout from worn bearings, shaft deflection |
| Uneven wear track | Face distorted by uneven or overtightened gland bolts, poor gland support |
| Scored faces | Dirt during assembly, abrasive solids in the liquid |
Swollen, soft or sticky O-rings point to an elastomer that does not suit the liquid or the lubricant. Fix the cause along with the parts, or the next seal fails the same way.
Common Mistakes
- Tightening packing to stop the drip. It burns the packing and grooves the sleeve.
- Leaving setting clips on. The seal cannot float, and the faces or sleeve are damaged on start.
- Skipping the shaft checks. Runout and end play kill new seals.
Check Your Understanding
1. A pump's packing has stopped dripping and the gland is too hot to touch. What do you do?
Back the gland nuts off evenly until a steady drip returns, about one drop per second, and check that any flush to the lantern ring is on. If it will not settle, repack it and inspect the sleeve.
2. A stuffing box measures 3.000 inches, the sleeve is 2.250 inches and the box is 2.250 inches deep. What packing size and ring count do you need?
(3.000 - 2.250) ÷ 2 = 0.375 inch, so 3/8-inch packing. 2.250 ÷ 0.375 = 6 rings, less any space a lantern ring takes.
3. A failed seal's hard face is covered in fine radial cracks. The pump's supply tank ran empty last week. What happened?
Heat checking from dry running. Fix the low-level protection or start-up practice, or the next seal will fail the same way.
Key Takeaways
- Packing must leak to live. Aim for the maker's rate, about one drop per second, and never tighten it dry.
- Size packing from the box: (bore - sleeve) ÷ 2. Cut on a mandrel, seat each ring and stagger the joints 90 degrees.
- Check shaft runout, end play and finish before a seal goes in, against the seal maker's limits.
- Never run a mechanical seal dry, and remove cartridge setting clips before start-up.
- Read every failed seal and fix the cause along with the parts.